3. RESULT Mode
Step No.
Operation and state
Step 1
Test mode STOP state
Step 2
BASS button
Step 3
AUTO menu
Step 4
SKIP UP button x 2 times
(Or SKIP DOWN button x 8 times)
Step 5
RESULT menu
Step 6
PLAY button
Step 7
Indication of measurement value:
Tracking error offset
Step 8
SKIP UP button
Step 9
Indication of measurement value:
Focus error offset
Step 10
SKIP UP button
Step 11
Indication of measurement value:
High reflection focus gain
Step 12
SKIP UP button
Step 13
Indication of measurement value:
High reflection pit tracking gain
Step 14
SKIP UP button
Step 15
Indication of measurement value:
High reflection pit tracking balance
Step 16
SKIP UP button
• Reversing when the SKIP DOWN button is pressed
• When the VOL UP button is pressed during set value indication, the set value increases, and the new set value is stored in RAM.
• When the VOL DOWN button is pressed during set value indication, the set value decreases, and the new set value is stored in RAM.
• When the VOL UP/DOWN button is held down, the setting changes continuously, one cycle being 100 ms.
• When the STOP button is pressed while the RESULT menu appears, or during measurement value or set value indication, the mode
changes to the TEST mode stop state.
: Measurement value
: Set value
7. TEST/PLAY Mode
Step No.
Operation and state
Step 1
Test mode STOP state
Step 2
BASS button
Step 3
AUTO menu
Step 4
SKIP UP button x 3times
(Or SKIP DOWN button x 7 times)
Step 5
TEST-PLAY menu
Step 6
When the DISP button is pressed, the
process proceeds to (7).
When the PLAY button is pressed, the
process proceeds to (9).
Step 7
TEST-PLAY mode
Step 8
PLAY button
Step 9
Continuous playback (pit section)
Continuous playback (groove section)
Step 10
STOP button
Step 11
Test mode STOP state
Step No.
Display
[
T E S T
]
Step 17
Step 18
[
A U T O
]
Step 19
Step 20
[
R E S U L T
]
Step 21
[ T E O :
]
Step 22
Step 23
[ F E O :
]
Step 24
Step 25
[ H f _ _
]
Step 26
Step 27
[ H g _ _
]
Step 28
Step 29
[ H b _ _
]
Display
[
T E S T
]
[
A U T O
]
[ T _ P L A Y
]
[ A d 0 0 5 0
]
[ S Q
]
[ A P
]
[
T E S T
]
– 11 –
MD-MS200W/MD-MS200/MD-MS200H
Operation and state
Indication of measurement value:
Low reflection focus gain
SKIP UP button
Indication of measurement value:
Low reflection tracking gain
SKIP UP button
Indication of measurement value:
Low reflection pit tracking balance
SKIP UP button
Indication of measurement value:
Low reflection TOTAL signal level
SKIP UP button
Indication of measurement value:
Low reflection groove tracking gain
SKIP UP button
Indication of measurement value:
Low reflection groove tracking balance
STOP button
Test mode STOP state
Display
[ L f _ _
]
[ L g _ _
]
[ L b _ _
]
[ G l _ _
]
[ G g _ _
]
[ G b _ _
]
[
T E S T
]