Culligan Aqua-Cleer Owner's Manual page 26

Advanced drinking water systems
Table of Contents

Advertisement

Performance
Data Sheet
(con't)
26
RO30 with AS3, TD (continued)
Fluoride
8.0 +/- 10%
Lead
0.15 +/- 10%
Nitrate/Nitrite (both as
30 +/- 10%
N)
Nitrate
27.0 +/- 10%
5
Nitrite
3.0 +/- 10%
Radium 226/2283
25pCi/L +/- 10%
Selenium
0.10 +/- 10%
Cyst
>50,000/mL
4
Turbidity
11 +/- 1 NTU
1 While testing was performed under standard laboratory conditions, actual performance may vary depending on water pressure, temperatures and
other substances, which may be found in your water.
2 This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5) or arsenate) at concentrations
of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water
supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pen-
tavalent arsenic. Treatment with chloramines (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent
arsenic. Please see the Arsenic Facts Sheet for further information.
3 Based upon testing methods using Barium as a surrogate. All concentrations in pCi/L pico curie/L.
4 Includes Giardia lamblia, Entamoeba histolyca and Cryptosporidium.
5 Units are not certified on water supplies with a pressure less than 40 psi (280 kPa). A booster pump is strongly recommended.
AS3
The AS3 has been tested according to NSF/ANSI 53 for the reduction of the substances
listed below. The concentration of the indicated substances in the water entering the
system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 53. Conforms to NSF/ANSI Standard 53 for
arsenic (trivalent and pentavalent) reduction. See Arsenic Fact section for an explanation
of reduction performance.
Substance
Influent
Challenge
Concentration
mg/L
Standard 53
Trivalent Arsenic pH 6.5 0.050 + 10%
Trivalent Arsenic pH 8.5 0.050 + 10%
Pentavalent Arsenic
0.050 + 10%
Flow Rate = 0.035 gpm (0.13 Lpm)
Capacity = 1000 gallons (3786 L)
1000 gallon capacity is only for use with PID
Testing was performed under standard laboratory conditions, actual performance may vary
1.5
0.010
10.0
1.0
5pCi/L
0.05
99.95%
0.5 NTU
Maximum
Reduction
Permissible
Require-
Product
ments
water Con-
centration
mg/L
0.010
0.010
0.010
95.6%
98.7%
83.1%
86.8%
83.4%
87.0%
79.5%
84.8%
80.0%
96.0%
99.99%
99.99%
99.00%
Minimum
Average
Reduction
Reduction
94.9%
98.0%
97.4%