3.5 Fuse Indicators

The PA2000 consists of four field-replacable power modules with two amplifiers in
each module. If a module fails, it may be replaced while the unit continues to
operate (at a reduction in output power).
Each of the paralleled amplifiers is protected by a 10 ampere fast-acting fuse.
When a fuse opens, the indicator light next to it comes illuminates and built-in
redundancy allows the unit to continue operation. The fuse can be replaced while
the unit is operating. Fuses 1 and 2 represent amplifiers 1 and 2 on the top left
module. Fuses 3 and 4 represent amplifiers 3 and 4 on the top right module. Fuses
5 and 6 represent amplifiers 5 and 6 on the lower left power module. Fuses 7 and 8
represent amplifiers 7 and 8 on the lower right power module.
Power Out
PA1
PA5
PA2
PA6
PA Temp
PA Voltage
PA3
PA7
PA4
PA8
Tot Current
3–8
Fault
Antenna
PA1
PA2
PA3
PA4
RF Drive
PA Temp
PA DC
Illustration 3–9 Fuse Indicators
Fuses and Indicators
Fuses
PA5
PA6
PA7
PA8