Troubleshooting Guide; Start Up Conditions; Thermal Expansion; Strange Sounds - Kenmore 153.321160 Use & Care Manual

60 gallon/80 gallon hybrid electric water heater
Table of Contents

Advertisement

Start Up Conditions

THERMAL EXPANSION

As water is heated, it expands (thermal expansion). In a closed
system, the volume of water will grow. As the volume of water
grows, there will be a corresponding increase in water pressure
due to thermal expansion. Thermal expansion can cause
premature tank failure (leakage). This type of failure is not
covered under the limited warranty. Thermal expansion can also
cause intermittent temperature-pressure relief valve operation:
water discharged from the valve due to excessive pressure build
up. The temperature-pressure relief valve is not intended for the
constant relief of thermal expansion. This condition is not covered
under the limited warranty.
A properly-sized thermal expansion tank should be installed
on all closed systems to control the harmful effects of thermal
expansion. Thermal expansion tanks are available from Sears
stores and through the Sears Service Centers. Contact the local
plumbing inspector, water supplier and/or the Sears Service
Center for assistance in controlling these situations.
Table 3: Thermal Expansion Tank Specifications
Model
Tank
Capacity
Number
In Gallons
Diameter
153.331020
2
8 (203 mm)
153.331050
5
11 (279 mm)
Table 4: Expansion Tank Sizing Chart
Inlet*
Water
Pressure
Expansion
40psi
Tank
Capacity
50psi
Needed
60psi
70psi
80psi
*Highest recorded inlet water pressure in a 24 hour period or
regulated water pressure.
TROUBLESHOOTING
Dimensions
Pipe
in Inches
Fitting
On Tank
Length
12-3/4" (323 mm)
3/4"Male
14-3/4" (375 mm)
3/4"Male
Water Heater Capacity
(Gallon)
30
40
50
66
2
2
2
5
2
2
2
5
2
2
5
5
2
2
5
5
2
5
5
5
NOTE: Expansion tanks are pre-charged with a 40 psi air
charge. If the inlet water pressure is higher than 40 psi, the
expansion tank's air pressure must be adjusted to match
that pressure, but must not be higher than 80 psi.

STRANGE SOUNDS

Possible noises due to expansion and contraction of some metal
parts during periods of heat-up and cool-down do not represent
harmful or dangerous conditions.

Operational Conditions

POWERED ANODE ROD OPERATION

To shelter the glass-lined water tank from corrosion through
82
electrolysis, this water heater is equipped with a non-sacrifi cial
5
powered anode which should not need to be replaced under
5
normal operating conditions. NOTE: The powered anode oper-
5
ates only when electrical power is applied.
5
If the powered anode malfunctions it should be replaced by a
5
qualifi ed technician.
IMPORTANT: If a faulty powered anode is not repaired or has
been removed permanently, then all warranties are void.
21
FIGURE 22.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.321180Elite 153.321160Elite 153.321180

Table of Contents