Air" In Hot Water Faucets; Rumbling Noise; High Temperature Shut Off System - Kenmore 153.321160 Use & Care Manual

60 gallon/80 gallon hybrid electric water heater
Table of Contents

Advertisement

"AIR" IN HOT WATER FAUCETS

HYDROGEN GAS: Hydrogen gas can be produced in a hot
water system that has not been used for a long period of time
(generally two weeks or more). Hydrogen gas is extremely
fl ammable and explosive. To prevent the possibility of injury
under these conditions, we recommend the hot water faucet
be opened for several minutes at the kitchen sink before any
electrical appliances which are connected to the hot water
system are used (such as a dishwasher or washing machine).
If a fault is detected by the system, an error message will be
displayed on the MAIN screen indicating the general nature
of the fault. More detailed fault information can be obtained
by viewing the MAINTENANCE screen. The MAINTENANCE
screen is accessed by simultaneously actuating the UP and
DOWN arrows on the user interface touch pad for 3 seconds.
(Note: engaging the child lock feature will not prevent access
to the MAINTENANCE screen, but will prevent inadvertent
changing of the set point temperature.)
changes to MAINTENANCE, use the up arrow to scroll to
the error messages. There are six (6) system temperature
messages display in succession, followed by four (4) stored
fault messages. Fault messages are stored newest to oldest
and are labeled EO1 - EO4. Utilize the DIAGNOSTIC CODES
table for explanation of what each fault message means and
corrective action steps for each."
If hydrogen gas is present, there will probably be an unusual
sound similar to air escaping through the pipe as the hot water
faucet is opened. There must be no smoking or open fl ame near
the faucet at the time it is open.

RUMBLING NOISE

In some water areas, scale or mineral deposits will build up on
your heating elements. This buildup will cause a rumbling noise.
Follow Element Removal/Replacement instructions to clean and
replace the elements.

HIGH TEMPERATURE SHUT OFF SYSTEM

This water heater is designed to automatically shut-off in the
event that the water temperature exceeds 190°F or 87.8°C.
A temperature limit switch or ECO (Energy Cut Off) is used
to shut off the power to the system if the water temperature
exceeds 190°F or 87.8°C (See "Water Temperature Regulation"
section). To reset the ECO disconnect power at the circuit
breaker/fuse box then remove the upper access panel. Reset
the ECO by fi rmly pushing in the red reset button located on the
ECO block. If the ECO continues to shut-off the water heater
contact a qualifi ed person for service.
DIAGNOSTIC CODES
System temperature parameters are available on the
MAINTENANCE screen to aid in assessing the operation of the
heat pump. Access the MAINTENANCE screen as described in
the preceding paragraph. Scroll through the parameters using
the UP and DOWN arrows. The six (6) system temperatures
are listed in the following order:
Once the screen
22
AMBIENT TEMPERATURE
TANK TEMPERATURE (average)
UPPER TANK TEMPERATURE
LOWER TANK TEMPERATURE
DISCHARGE TEMPERATURE (compressor discharge)
COIL TEMPERATURE (evaporator coil outlet)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.321180Elite 153.321160Elite 153.321180

Table of Contents