Download Print this page

Operating Instructions - Aktakom APS-3310 User Manual

Single output dc bench power supplies with large digital display

Advertisement

Operating Instructions:

1. Press the power on/off button to turn power on.
2. Adjust the voltage knob to set the desired voltage. (Voltage level is shown on the digital dis-
play)
3. Adjust the current level pot with a small regular screwdriver to set the (maximum) desired cur-
rent level. (The current of the power supply is set to be the maximum at the factory)
4. Connecting a load to the output terminals and pressing the output switch will illuminate the
output indicator light and the current output can be read on the digital display.
5. The sampling terminals are not often used. Use them under the following conditions: If the load
has a distance from the power supply, the sampling terminals may be used to compensate for the
inherent when using voltage drop a longer power line.
Sampling connection diagram:
Attention: Disconnect the installed S- and S+ shorting wires when using the sampling connections.
www.tmatlantic.com

Advertisement

loading

This manual is also suitable for:

Aps-3610