3. Place the sand fill cover over
the tank opening to prevent the
sand from getting into the
standpipe.
4. Fill the tank approximately 1/2
full of water.
5. Pour the recommended amount
of sand into the tank, making sure
that the standpipe remains
centered and vertical. Level the
surface upon completion.
6. Remove the sand-fill cover.
7. Preassemble the clamps with
one screw and one nut, turning
the screw 3-4 turns only.
8. Carefully remove all sand
particles from the valve mounting
surfaces.
9. Place the O-Ring onto the
bottom of the valve body.
10. Lower the dial valve carefully
into position so that its underside
engages with the standpipe.
Rotate the valve until the inlet is
approximately in line with the
pump.
11. Place clamps around tank
and valve neck and assemble
second screw and nut.
12. Firmly tap with a rubber mallet
outside of the clamps as you
tighten both screws alternately
and evenly.
13. Make sure screws are
tightened until clamps are
completely closed.
14. Install the pressure gauge
into the threaded opening in the
dial valve.
15. Install the backwash adapter,
if necessary, to reduce backwash flow.
Install 2 threaded adapters into pump
discharge and dial valve inlet after
wrapping threads with 4 to 8 wraps of
Teflon tape. Place one hose clamp over
each end of pump to filter hose and
push hose on to each adapter. Position
clamps over barbed portion of adapter
and tighten.
You are now ready to connect the sys-
tem to your pool.
ELECTRICAL DATA
Refer to information on motor nameplate for electri-
cal service data. If the pump on your system is sup-
plied with a 3-prong twist lock 115V plug, then the
appropriate female receptacle should be installed.
Connect only to a grounding type receptacle pro-
tected by a Ground Fault Circuit Interrupter
(GFCI). Motors should have fused disconnect switch
or circuit breaker and wire size large enough for pump
horsepower and distance from power source. Wiring
should be done in accordance with applicable codes
by a competent electrician.
CAUTION
!
low voltage which can damage pump motor,
use minimum wire gauge.

PLUMBING CONNECTIONS

The provision of gate valves and unions in the pump suction and pool return lines
of a permanent installation will make servicing easier and prevent loss of water while
routine maintenance is in progress. Pump Installation: Follow the instructions
supplied with the pump. Connect the pipes to the filter system as shown on page 2.
Sand Fill Cover Assembly
7 Position Dial Valve Installation
Clamp
Screw
Clamp Installation
Clamps are
completely
closed
Dial Valve Inlet
Pump Discharge
twist-lock plug
Standard
3-prong
Wire Length
To guard against
HP
3/4
1
Do not use pipes smaller than the connections provided. Support the plumbing
so that it puts no strain on either the pump or the filter.
Rigid or flexible PVC pipe can be used. Pipe ends should be clean and free of
any debris caused by the cutting operation. Be sure that the proper adhesive
is used on the type of pipe specified. Recommended Adhesives: These are
examples only and are not intended to restrict brands:
PVC-PVC Joint
Uni-Weld Pool-Tite 2000
Suregard Flex 20
IPS Weld-On 705
Note: A primer will assure that adhesive joints are superior. Suregard P-3000
has a purple tracer to qualify in areas where codes specify a primer must be
used.
Caution: We recommend that you consider climatic conditions when applying
adhesives. Certain atmospheric situations, such as high moisture content,
make the adhesive action of certain glues less effective. Check the
O-Ring
manufacturer's instructions.
Clamp
Bolt
Use only Teflon tape or equivalent on threaded plumbing connections. Other
Clamp
pipe compounds may damage threads. We do not recommend the use of
silicone or petroleum based compounds. DO NOT OVER-TIGHTEN: HAND-
TIGHTEN PLUS 1/2 TURN IS SUFFICIENT.
If the filter is equipped with union connections, union adapters are needed to
complete plumbing connections and may need to be ordered separately.
You are now ready to fill your pool and begin system start-up procedures.
CAUTION
!
For above-ground pools with sys-
tem below the pool water level:
1a. Press down on the valve handle
and rotate to the FILTER position
and release. Pool water will flow into
the filter tank, pump and strainer.
When water level reaches the clear
strainer cover on the pump, the fil-
ter is ready for operation. NOTE: If
an optional shut-off valve is in-
stalled, be sure that it is fully
opened.
For in-ground pools with system
above the pool water level:
1b. Unscrew the Ring-Lok nut on the
pump and remove the clear strainer
cover. Prime the pump by filling the
strainer with water to the bottom of
the inlet. Replace the clear cover and
Ring-Lok nut. HAND-TIGHTEN
ONLY.
3-prong
2. Turn the motor on (for only a few
seconds) by plugging the unit into the
Grounded electrical receptacle.
plug
WARNING
WARNING
WARNING
WARNING
WARNING
!
When it has been determined that
the pump motor is operating prop-
50 ft.
100 ft.
erly, stop the pump and proceed to
#14G
#12G
Step 3.
#12G
#10G
3. A) Set dial valve to DRAIN posi-
tion.
B) Start pump.
C) After flow has been established,
stop pump.
D) Set valve to BACKWASH posi-
tion.
FOR SOLVENT WELD CONNECTIONS
PVC-ABS Joint
Uni-Weld Pool-Tite 2000
Suregard Weld-All No. 5
IPS Weld-On 794
FOR THREADED CONNECTIONS
FILTER PLUMBING

SYSTEM START-UP

Do not operate your pump until it has been
filled with water (primed).
OR
DO NOT USE AN
EXTENSION CORD.
Backwash
Priming
Level
3

Hide quick links:

Advertisement

loading

This manual is also suitable for:

L160cAquamax 160cAtl190cL190cAtl192cL192c ... Show all