Troubleshooting - Guest Trolling Charger 2607A Owner's Manual

Trolling charger series on board battery chargers
Table of Contents

Advertisement

4. TROUBLESHOOTING

Problem
1. Red LED stays
on for more than
24 Hrs.
2. The red and
green LED's stay
on for more than
24 Hrs.
3. Green LED stays
on when the
battery is known
to be low.
3. Neither of the
LED's turn on
when the AC
power is applied.
Cause
1. One or more defective or
damaged cells.
2. Charger has reduced its output
voltage below the normal level
due to a DC overload or a DC
short.
3. On-board DC systems are
drawing more current than the
charger can replace.
1. On-board DC systems are
drawing between 1.5 – 3.5A.
2. One or more defective or
damaged cells.
3. Extremely low AC voltage at
the battery charger.
1. Open circuit breaker or DC
output fuse.
2. Faulty or contaminated
terminal connections.
3. One or more defective or
damaged cells.
1. No AC power available at the
charger
2. Charger failure
Solution
1. Load test the batteries and
replace if necessary.
2. Remove the source of the
overload or short. Disconnect
the charger's black
(NEGATIVE) ring terminal from
the battery. Reapply AC power
and the green LED only should
now light.
3. Turn off all DC equipment while
charging.
1. Turn off all DC equipment while
charging.
2. Load test the batteries and
replace if necessary.
3. Apply a higher AC voltage
source or reduce the length of
the extension cord.
4. Check battery manufacturer's
specs on battery charging.
1. Check connections to the
battery, reset circuit breaker if
equipped/replace fuse..
2. Clean and tighten or repair all
terminal connections.
3. Load test the batteries and
replace if necessary.
1. Connect AC power or reset the
AC breaker on the main panel
2. Return charger to the Guest
Service Dept.
14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents