2
Figure 15.
Venting with three 90° elbows
18
VENTING WITH THREE (3) 90° ELBOWS
H
1
V
1´MIN. (305mm)
2´MIN. (610mm)
3´MIN. (914mm)
4´MIN. (1.22m)
V+H+H
Heat & Glo • 6000TRXI-IPI • 386-901 Rev. I • 1/06
V
H
1´MIN. (305mm)
2´MAX. (610mm)
2´MIN. (610mm)
4´MAX. (1.22m)
3´MIN. (914mm)
6´MAX. (1.86m)
4´MIN. (1.22m)
8´MAX. (2.48m)
V
+V+H+H
= 40
MAX.(12.4 m) H = 8´MAX.(2.48 m) H+H
´
1
1
V
H
H
2´MAX. (610mm)
4´MAX. (1.22m)
6´MAX. (1.86m)
8´MAX. (2.48m)
+H
= 40
MAX. (12.4 m)