Fixed Glass Assembly; Install The Mesh; Air Shutter Setting - Heat & Glo Escape-42DV Owner's Manual

Natural gas
Hide thumbs Also See for Escape-42DV:
Table of Contents

Advertisement

G. Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle fi xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
• DO NOT strike, slam or scratch glass.
• DO NOT operate fi replace with glass removed, cracked,
broken or scratched.
• Replace as a complete assembly.
Removing Fixed Glass Assembly
• Remove the ash lip that is located in front of the glass.
• Remove the side panels located in front of the glass.
• Remove the pull mesh fi rescreen by unhooking from the
fi replace.
• Pull and release the six glass latches (3 per side) located
on the sides of the glass frame.
• Grasping the upper lip with one hand and the lower lip
with the other, pull the bottom of the glass out fi rst. Guide
the bottom while letting the top drop down under the top
of the opening (see Figure 14.1).
Replacing Fixed Glass Assembly
• Replace the glass door on the appliance. Pull out and
latch the six glass assembly latches into the groove on
the glass frame.
UPPER
LIP
GLASS
CLIP
Figure 14.1 Fixed Glass Assembly
H. Install the Mesh
The pull-type fi rescreen hangs on the three hanger brack-
ets located above the glass.
52
Heat & Glo • Escape-42DV • 2052-900 Rev. X • 3/11
I. Air Shutter Setting
Air shutter settings should be adjusted by a qualifi ed ser-
vice technician at the time of installation. The air shutter
is set at the factory for minimum vertical vent run. Adjust
air shutter for longer vertical runs.
NOTICE: If sooting occurs, provide more air by opening
the air shutter.
Air Shutter Settings
ESCAPE42-DV
ESCAPE42-DVLP
NG
LP
3/8 in.
N/A
N/A
11/16 in.

Advertisement