Page 4
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 7.4.2 ..........................63 ETTINGS 7.4.3 ........................63 ASS HROUGH ............................. 64 IRELESS 7.5.1 ........................64 IRELESS ETWORK 7.5.2 ........................
Page 5
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Revision History Version Date Remark 1.0 Aug 24, 2008 Initial Version 2.0 Jul 28, 2009 New Feature and Functions Included for firmware v1.0.39 ...
To protect wireless connectivity, EOC1650 encrypt wireless transmissions through 64/128‐bit WEP data encryption and also supports WPA/WPA2. The MAC address filter lets you select exactly which stations should have access to your network. In addition, the User Isolation function can protect the private network between client users. The attractive design, high performance, and array of features make EOC1650 an optimal wireless solution choice for your residence and office. 1.1 Features Wireless ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Security 802.11i WEP, WPA, WPA2 (Encryption support TKIP/AES) MAC address functions MAC address filter (AP mode) 802.1x IEEE802.1x Authenticator Station isolation Management Firmware Upgrade Upgrading firmware via web browser, setting are reserved after upgrade Reset & Backup Reset to factory default. User can export all setting into a file via WEB Ping & Trace Route Built‐in PING function & Trace Route function in Web GUI MIB MIB I, MIB II(RFC1213), Private MIB SNMP V1, V2c 1.2 Package Contents Open the package carefully, and make sure that none of the items listed below are missing. Do not ...
Page 8
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 established and removed. The ability to access real‐time information Doctors/nurses, point‐of‐sale employees, and warehouse workers can access real‐time information while dealing with patients, serving customers and processing information. d) Frequently changed environments Show rooms, meeting rooms, retail stores, and manufacturing sites where frequently rearrange the workplace. e) Small Office and Home Office (SOHO) networks SOHO users need a cost‐effective, easy and quick installation of a small network. Wireless extensions to Ethernet networks Network managers in dynamic environments can minimize the overhead caused by ...
2 Understanding the Hardware 2.1 Hardware Installation 1. Place the unit in an appropriate location after conducting a site survey. 2. Plug one end of the Ethernet cable into the Network port of the PoE injector and another end into your PC/Notebook. 3. Plug one end of another Ethernet cable to AP/Bridge port of the PoE injector and the other end into you cable/DSL modem (Internet) 4. Insert the DC‐inlet of the power adapter into the 24V port of the PoE injector and the other end into the power socket on the wall. This diagram depicts the hardware configuration 2.2 Hardware Description ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 2.3 Mounting Kits The images below depict the standard mounting kits. Pole Mount Wall Mount Window Mount ...
Page 11
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 2. Select Internet Protocol (TCP/IP) and then click on the Properties button. This will allow you to configure the TCP/IP settings of your PC/Notebook. 3. Select Use the following IP Address radio button and then enter the IP address and subnet mask. Ensure that the IP address and subnet mask are on the same subnet as the device. For Example: ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 3 Switching Between Operating Modes This device can operate in three modes: Access Point, Client Bridge, WDS Bridge and Client Router. This chapter will describe how to switch between operating modes. 3.1 Logging In To configure the device through the web‐browser, enter the IP address of the device (default: 192.168.1.1) into the address bar of the web‐browser and press Enter. Make sure that the device and your computer are configured on the same subnet. (Refer to ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 4 Access Point Operating Mode Logging In To configure the device through the web‐browser, enter the IP address of the device (default: 192.168.1.1) into the address bar of the web‐browser and press Enter. Make sure that the device and your computers are configured on the same subnet. Refer to ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Status Click on the Status link on the navigation drop‐down menu. You will then see three options: Main, Wireless Client List, and System Log. Each option is described in detail below. 4.2.1 Main Click on the Main link under the Status drop‐down menu. The status that is displayed ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 4.2.2 Wireless Client List Click on the Wireless Client List link under the Status drop‐down menu. This page displays the list of Clients that are associated to the Access Point. The MAC addresses and signal strength for each client is displayed. Click on the Refresh button to refresh the client list . 4.2.3 System Log Click on the System Log link under the Status drop‐down menu. The device automatically logs (records) events of possible interest in its internal memory. If there is not enough internal ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 4.3.1 System Properties Click on the System Properties link under the System drop‐down menu. This page allows you to switch the operating mode of the device, as well as specify a name and select the operating region. Device Name: Specify a name for the device (this is not the SSID), Country/Region: Select a country from the drop‐down list. Operating Mode: Select and operating mode. Configuration for each operating mode is ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 4.3.3 Spanning Tree Settings Click on the Spanning Tree link under the System drop‐down menu Spanning‐Tree Protocol is a link management protocol that provides path redundancy while preventing undesirable loops in the network. Spanning Tree Status: Choose to enable or disable the spanning tree feature. Bridge Hello Time: Specify the number of seconds for the hello time. Bridge Max Age: Specify the number of seconds for the max age. Bridge Forward Delay: Specify the number of seconds for the bridge forward delay. Priority: Specify the number of seconds for the priority. Click on the Apply button to save the changes. 4.4 Wireless Click on the Wireless link on the navigation drop‐down ...
Page 18
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Wireless Mode: Depending on the type of wireless clients that are connected to the network, you may select B, G or B/G‐mixed. If you are not sure about which clients will be accessing the wireless networks, it is recommended that you select B/G‐mixed for the best performance. Channel / Frequency: Select a channel from the drop‐down list. The channels available are based on the country’s regulation. Current Profiles: User can setup SSID configuration in this item. EOC1650 supports 4 SSIDs, user can decide to use how many SSID via “Enable” or not. When click “Edit” button, you can setup detail, include SSID, VLAN ID and Security Mode. Wireless Security – Security Mode : WEP ...
Page 19
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Security Mode: Select WEP from the drop‐down list if your wireless network uses WEP encryption. WEP is an acronym for Wired Equivalent Privacy, and is a security protocol that provides the same level of security for wireless networks as for a wired network. Authentication Type: Select an authentication method. Options available are Open Key, Shared Key. An open system allows any client to authenticate as long as it conforms to any ...
Page 20
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Security Mode: Select WPA‐PSK, WPA2‐PSK, or WPA‐PSK Mixed from the drop‐down list if your wireless network uses WPA pre‐shared key. Encryption: Select TKIP or AES from the drop‐down list if your wireless network uses this encryption. WPA (Wi‐Fi Protected Access) was designed to improve upon the security features of WEP (Wired Equivalent Privacy). The technology is designed to work with existing Wi‐Fi ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Security Mode: Select WPA, WPA2 or WPA Mixed from the drop‐down list if your wireless network uses WPA. WPA (Wi‐Fi Protected Access) was designed to improve upon the security features of WEP (Wired Equivalent Privacy). The technology is designed to work with existing Wi‐Fi products that have been enabled with WEP. WPA provides improved data encryption through the Temporal Integrity Protocol (TKIP), which scrambles the keys using a hashing algorithm and by adding an integrity checking feature which makes sure that keys haven’t been tampered with. Encryption: Select TKIP or AES from the drop‐down list if your wireless network uses this encryption. RADIUS Server: Enter the IP address of the RADIUS server. RADIUS Port: Enter the port number of the RADIUS server. The default is usually 1812. RADIUS Secret: Enter the shared password of the RADIUS server. Group Key Update Interval: Specify the number of seconds after which the Access Point will ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 ACL (Access Control) Mode: You may choose to Disable, Allow Listed, or Deny Listed MAC addresses from associating with the network. By selecting Allow MAC in the List, only the ...
Page 23
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Data Rate: If you would like to force a data rate, you may select one from the drop‐down list. However, for best performance it is recommended to use the Auto setting. Transmit Power: You may have the different application distance of the device by selecting a value from the drop‐down list. This feature can be helpful in restricting the coverage area of the ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Management Click on the Management link on the navigation drop‐ down menu. You will then see seven options: administration, SNMP settings, backup/restore settings, firmware upgrade, time settings, and log. Each option is described below. ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Name: Specify a user name into the first field. Password: Specify a password into this field and then re‐type the password into the Confirm Password field. Click on the Apply button to save the changes. 4.5.3 SNMP Settings Click on the SNMP Settings link under the Management menu. This option allows you to assign the contact details, location, and community name and trap settings for SNMP. This is a ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Save a copy of the current settings: Click on the Backup button to save the current configuration. Restore saved settings from a file: Once a file has been backed up, you may restore it by clicking on the Browse button to select the file, and then the Restore button. Revert to factory default settings: Click on the Factory Default Settings button to reset the device to the default settings. Please wait while the device restart and then access the device ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Manually Set Date and Time: Specify the date and time Automatically Get Date and Time: Select the time zone from the drop down list and then specify the IP address of the NTP server. Click on the Apply button to save the changes. 4.5.7 Log Click on the Log link under the Management menu. The Log page displays a list of events that are triggered on the Ethernet and Wireless interface. This log can be referred when an unknown error occurs on the system or when a report needs to be sent to the technical support ...
Page 28
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Ping Test Parameters : User can input Target IP, Ping Size and Ping Quantity of other network device which connected you want. And then you can find the ping condition after click Start Ping. Traceroute Test Parameters: This function help user to monitor a network trace. User can input IP or domain name on Traceroute target. ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 5 Client Bridge Operating Mode Logging In To configure the device through the web‐browser, enter the IP address of the device (default: 192.168.1.1) into the address bar of the web‐browser and press Enter. Make sure that the device and your computers are configured on the same subnet. Refer to ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Status Click on the Status link on the navigation drop‐down menu. You will then see three options: Main, Connection Status, and System Log. Each option is described in detail below. 5.2.1 Main Click on the Main link under the Status drop‐down menu. The status that is displayed ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 5.2.3 System Log Click on the System Log link under the Status drop‐down menu. The device automatically logs (records) events of possible interest in its internal memory. If there is not enough internal ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 System Click on the System link on the navigation drop‐down menu. You will then see three options: System Properties, IP Settings, and Spanning Tree Settings. Each option is described in detail below. 5.3.1 System Properties Click on the System Properties link under the System drop‐down menu. This page allows you to switch the operating mode of the device, as well as specify a name and select the operating ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 device to use a static IP address. In this case, you would be required to specify an IP address, subnet mask, and default gateway IP address. IP Address: Specify an IP address IP Subnet Mask: Specify the subnet mask for the IP address Default Gateway: Specify the IP address of the default gateway. Click on the Apply button to save the changes. 5.3.3 Spanning Tree Settings Click on the Spanning Tree link under the System drop‐down menu Spanning‐Tree Protocol is a ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Wireless Mode: Depending on the type of wireless clients that are connected to the network, you may select B, G, or B/G‐mixed. If you are not sure about which clients will be accessing the wireless networks, it is recommended that you select B/G‐mixed for the best performance. SSID: The SSID is a unique named shared amongst all the points of the wireless network. The SSID must be identical on all points of the wireless network and cannot exceed 32 characters. You may specify an SSID or select one from the Site Survey. Site Survey: Click on the Site Survey button in order to scan the 2.4GHz frequency for devices ...
Page 35
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Security Mode: Select WEP from the drop‐down list if your wireless network uses WEP encryption. WEP is an acronym for Wired Equivalent Privacy, and is a security protocol that ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Encryption: Select TKIP or AES from the drop‐down list if your wireless network uses this encryption. WPA (Wi‐Fi Protected Access) was designed to improve upon the security features of WEP (Wired Equivalent Privacy). The technology is designed to work with existing Wi‐Fi products that have been enabled with WEP. WPA provides improved data encryption through the ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Data Rate: If you would like to force a data rate, you may select one from the drop‐down list. However, for best performance it is recommended to use the Auto setting. Transmit Power: You may have the different application distance of the device by selecting a value from the drop‐down list. This feature can be helpful in restricting the coverage area of the ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Name: Specify a user name into the first field. Password: Specify a password into this field and then re‐type the password into the Confirm Password field. Click on the Apply button to save the changes. 5.5.2 SNMP Settings Click on the SNMP Settings link under the Management menu. This option allows you to assign the contact details, location, and community name and trap settings for SNMP. This is a ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 5.5.3 Backup/Restore settings, Reset to factory default settings Click on the Backup/Restore Setting link under the Management menu. This option is used to save the current settings of the device in a file on your local disk or load settings on to the device from a local disk. This feature is very handy for administrators who have several devices that ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 5.5.5 Time Settings Click on the Time Settings link under the Management menu. This page allows you to configure the time on the device. You may do this manually or by connecting to a NTP server. Manually Set Date and Time: Specify the date and time Automatically Get Date and Time: Select the time zone from the drop down list and then specify the IP address of the NTP server. Click on the Apply button to save the changes. 5.5.6 Log Click on the Log link under the Management menu. The Log page displays a list of events that are triggered on the Ethernet and Wireless interface. This log can be referred when an unknown ...
Page 41
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Ping Test Parameters : User can input Target IP, Ping Size and Ping Quantity of other network device which connected you want. And then you can find the ping condition after click Start Ping. Traceroute Test Parameters: This function help user to monitor a network trace. User can input IP or domain name on Traceroute target. ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 6 WDS Bridge Operating Mode 6.1 Logging In To configure the device through the web‐browser, enter the IP address of the device (default: 192.168.1.1) into the address bar of the web‐browser and press Enter. Make sure that the device and your computers are configured on the same subnet. Refer to Chapter 2 in order to configure the IP address of your computer. After connecting to the IP address, the web‐browser will display the login page. Specify admin for both the user name and password. ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 6.2 Status Click on the Status link on the navigation drop‐down menu. You will then see three options: Main, WDS Link Status, and System Log. Each option is described in detail below. 6.2.1 Main Click on the Main link under the Status drop‐down menu. The status that is displayed ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 6.2.2 WDS Link Status Click on the WDS Link Status link under the Status drop‐down menu. This page displays the current status of the WDS Link, including Station ID, MAC address, Status, RSSI(Received Signal Strength Indicator). 6.2.3 System Log Click on the System Log link under the Status drop‐down menu. The device automatically ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 6.3 System Click on the System link on the navigation drop‐down menu. You will then see System Properties, IP Settings and Spanning Tree Settings. 6.3.1 System Properties Click on the System Properties link under the System drop‐down menu. This page allows you to switch the operating mode of the device, as well as specify a name and select the ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 IP Network Setting: Select Obtain an IP address automatically (DHCP) radio button if the Access Point is connected to a DHCP server. This will allow the Access Point to pass IP addresses to the clients associated with it. You may select Specify an IP Address radio ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 6.4.1 Wireless Network The Wireless Network page allows you to configure the wireless mode, channel, SSID, and security settings. Wireless Mode: Depending on the type of wireless clients that are connected to the network, you may select B, G or B/G‐mixed. If you are not sure about which clients will be accessing the wireless networks, it is recommended that you select B/G‐mixed for the best performance. Channel/Frequency: Select a channel from the drop‐down list. The channels available are ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 MAC Address: you can input the MAC address of WDS device, which you want to link. Mode: Enable to connect, and Disable to disconnect. Click on the Apply button to save the changes. 6.4.3 WDS Security Security Mode: Select WEP from the drop‐down list if your wireless network uses WEP encryption. WEP is an acronym for Wired Equivalent Privacy, and is a security protocol that provides the same level of security for wireless networks as for a wired network. WEP Key: Select a key format from the drop‐down list. 64bit‐hex keys require 10 characters, ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Data Rate: If you would like to force a data rate, you may select one from the drop‐down list. However, for best performance it is recommended to use the Auto setting. Transmit Power: You may have the different application distance of the device by selecting a value from the drop‐down list. This feature can be helpful in restricting the coverage area of the wireless network. Fragment Length: Packets over the specified size will be fragmented in order to improve performance on noisy networks. RTS/CTS Threshold: Packets over the specified size will use the RTS/CTS mechanism to ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 6.5.1 Administration Click on the Administration link under the Management menu. This option allows you to create a user name and password for the device. By default, this device is configured ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Read‐Only Community Name: Specify the password for access the SNMP community for read only access. Read‐Write Community Name: Specify the password for access to the SNMP community with read/write access. Trap Destination IP Address: Specify the IP address of the computer that will receive the ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Click on the Browse button and then select the appropriate firmware and then click on the Upgrade button. Note: The upgrade process may take about 1 minute to complete. Do not power off the device during this process as it may crash the device and make it unusable. The device will restart automatically once the upgrade is complete. 6.5.5 Time Settings Click on the Time Settings link under the Management menu. This page allows you to ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Syslog: Choose to enable or disable the system log. Log Server IP Address: Specify the IP address of the server that will receive the system log. Local Log: Choose to enable or disable the local log. Click on the Apply button to save the changes. 6.5.7 Diagnostics Click on the Diagnostics link under the Management menu. In this page, user can let unit to ping other network equipment. And user also can monitor a route from unit to your target. Ping Test Parameters : User can input Target IP, Ping Size and Ping Quantity of other ...
7 Client Router Operating Mode 7.1 Logging In To configure the device through the web‐browser, enter the IP address of the device (default: 192.168.1.1) into the address bar of the web‐browser and press Enter. Make sure that the device and your computers are configured on the same subnet. Refer to Chapter 2 in order to configure the IP address of your computer. After connecting to the IP address, the web‐browser will display the login page. Specify admin for both the user name and password. After logging in you will graphical user interface (GUI) of the device. The navigation drop‐down menu on left is divided into four sections: ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Click on the Status link on the navigation drop‐down menu. You will then see four options: Main, DHCP Client Table, Connection Status and System Log. Each option is described in detail below. 7.2.1 Main Click on the Main link under the Status drop‐down menu. The status that is displayed ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 7.2.2 DHCP Client Table Click on the DHCP Client Table link under the Status drop‐down menu. This page displays the current status of all DHCP clients, including IP and expires information. 7.2.3 Connection Status Click on the Connection Status link under the Status drop-down menu. This page...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 7.2.4 System Log Click on the System Log link under the Status drop-down menu. The device automatically logs (records) events of possible interest in its internal memory. If there is not enough internal memory for all events, logs of older events are deleted, but...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 7.3 System Click on the System link on the navigation drop‐down menu. You will then see System Properties setting, which is described below. 7.3.1 System Properties Click on the System Properties link under the System drop‐down menu. This page allows ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 7.4.1.1 WAN ‐ DHCP The WAN interface can be configured as a DHCP Client in which the ISP provides the IP address to the device. This is also known as Dynamic IP. Internet Connection Type: Select the DHCP from the drop‐down list. Account Name: Specify an account name if your ISP has provided you with one. Domain Name: Specify a domain name if the ISP has provided you with one. MTU: The Maximum Transmission Unit (MTU) is a parameter that determines the largest ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Internet Connection Type: Select the Static IP from the drop‐down list. Account Name: Specify an account name if your ISP has provided you with one. Domain Name: Specify a domain name if the ISP has provided you with one. MTU: The Maximum Transmission Unit (MTU) is a parameter that determines the largest packet size (in bytes) that the router will send to the WAN. If LAN devices send larger ...
Page 61
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Internet Connection Type: Select PPPoE from the drop‐down list. MTU: The Maximum Transmission Unit (MTU) is a parameter that determines the largest packet size (in bytes) that the router will send to the WAN. If LAN devices send larger ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 7.4.1.4 WAN – PPTP The WAN interface can be configured as PPTP. This type of connection is usually used for a DSL service and requires a username and password to connect. Internet Connection Type: Select PPPoE from the drop‐down list. MTU: The Maximum Transmission Unit (MTU) is a parameter that determines the largest packet size (in bytes) that the router will send to the WAN. If LAN devices send larger ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 interface and click the Connect button manually any time that you wish to connect to the Internet. Domain Name Service: Select Get Automatically from ISP if the ISP will provide the DNS address, if not, select Use these DNS servers and specify the primary and secondary DNS ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 L2TP Pass Through: Place a check in this box if you would like to enable this pass through. Layer 2 Tunneling Protocol is a transport protocol that enables tunneling through the Internet for the establishment of virtual private networks. IPSec Pass Through: Place a check in this box if you would like to enable this pass through. IPSec is a VPN protocol used to implement secure exchange of packets at the IP layer. Click on the Apply button to save the changes. 7.5 Wireless Click on the Wireless link on the navigation drop‐down menu. You will then see three options: wireless ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 7.5.2 Wireless Security 7.5.2.1 Wireless Security : WEP Security Mode: Select WEP from the drop‐down list if your wireless network uses WEP encryption. WEP is an acronym for Wired Equivalent Privacy, and is a security protocol that provides the same level of security for wireless networks as for a wired network. Authentication Type: Select an authentication method. Options available are Open Key, ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Default Key: You may use up to four different keys for four different networks. Select the current key that will be used. Key 1‐4: You may enter four different WEP keys. Click on the Apply button to save the changes. 7.5.2.2 Wireless Security : WPA‐PSK, WPA2‐PSK, Security Mode: Select WPA‐PSK or WPA2‐PSK from the drop‐down list if your wireless network uses WPA pre‐shared key. Encryption: Select TKIP or AES from the drop‐down list if your wireless network uses this ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Data Rate: If you would like to force a data rate, you may select one from the drop‐down list. However, for best performance it is recommended to use the Auto setting. Transmit Power: You may have the different application distance of the device by selecting a value from the drop‐down list. This feature can be helpful in restricting the coverage area of the wireless network. Fragment: Packets over the specified size will be fragmented in order to improve performance on noisy networks. RTS Threshold: Packets over the specified size will use the RTS/CTS mechanism to maintain performance in noisy networks and preventing hidden nodes from degrading the ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 7.6.1 Administration Click on the Administration link under the Management menu. This option allows you to create a user name and password for the device. By default, this device is configured ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 SNMP Enable/Disable: Choose to enable or disable the SNMP feature. Contact: Specify the contact details of the device. Location: Specify the location of the device. Read‐Only Community Name: Specify the password for access the SNMP community for read only access. Read‐Write Community Name: Specify the password for access to the SNMP community ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Restore saved settings from a file: Once a file has been backed up, you may restore it by clicking on the Browse button to select the file, and then the Restore button. Revert to factory default settings: Click on the Factory Default Settings button to reset the device to the default settings. Please wait while the device restart and then access the device using the default IP address: 192.168.1.1 7.6.4 Firmware Upgrade ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Manually Set Date and Time: Specify the date and time Automatically Get Date and Time: Select the time zone from the drop down list and then specify the IP address of the NTP server. Click on the Apply button to save the changes. 7.6.6 Log Click on the Log link under the Management menu. The Log page displays a list of events that are triggered on the Ethernet and Wireless interface. This log can be referred when an unknown error occurs on the system or when a report needs to be sent to the technical ...
Page 72
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Ping Test Parameters : User can input Target IP, Ping Size and Ping Quantity of other network device which connected you want. And then you can find the ping condition after click Start Ping. Traceroute Test Parameters: This function help user to monitor a network trace. User can input IP or domain name on Traceroute target. ...
EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Appendix A – FCC Interference Statement Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection ...
Multi-Function Gigabit Wireless-N Client Bridge Version 1.0 Appendix B – IC Statement Industry Canada statement: This device complies with RSS‐210 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IMPORTANT NOTE: Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This device has been designed to operate with an antenna having a maximum gain of 5 dBi. Antenna having a higher gain is strictly prohibited per regulations of Industry Canada. The required antenna impedance is 50 ohms.