EnGenius EOC1650 User Manual

EnGenius EOC1650 User Manual

Wireless access point & client bridge
Hide thumbs Also See for EOC1650:
Table of Contents

Advertisement

Wireless Access Point & Client Bridge 
 
 
 
 
 
 
 
 
 
 
 
 
EnGenius EOC1650 
User's Manual
Version: 2.0
 
 
 

Advertisement

Table of Contents
loading

Summary of Contents for EnGenius EOC1650

  • Page 1 EnGenius EOC1650  Wireless Access Point & Client Bridge                          User’s Manual   Version: 2.0    ...
  • Page 2: Table Of Contents

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Table of Contents        INTRODUCTION ............................ 6     ............................6 EATURES     ......................... 7 ACKAGE  ONTENTS     ........................7 YSTEM  EQUIREMENTS     ..........................7 PPLICATIONS  ...
  • Page 3 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     5.3.3 ........................ 33 PANNING  REE  ETTINGS     ............................. 33 IRELESS     5.4.1 ........................33 IRELESS  ETWORK     5.4.2 ........................34 IRELESS  ECURITY     5.4.3 ......................
  • Page 4 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     7.4.2 ..........................63   ETTINGS     7.4.3 ........................63   ASS  HROUGH     ............................. 64 IRELESS     7.5.1 ........................64 IRELESS  ETWORK     7.5.2 ........................
  • Page 5 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Revision History    Version  Date  Remark  1.0  Aug 24, 2008  Initial Version  2.0  Jul 28, 2009  New Feature and Functions Included for firmware v1.0.39               ...
  • Page 6: Introduction

    To protect wireless connectivity, EOC1650 encrypt wireless transmissions through 64/128‐bit WEP data  encryption and also supports WPA/WPA2. The MAC address filter lets you select exactly which stations  should  have  access  to  your  network.  In  addition,  the  User  Isolation  function  can  protect  the  private  network between client users.    The  attractive  design,  high  performance,  and  array  of  features  make  EOC1650  an  optimal  wireless  solution choice for your residence and office.     1.1 Features   Wireless  ...
  • Page 7: Package Contents

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   Security    802.11i   WEP, WPA, WPA2 (Encryption support TKIP/AES)    MAC address functions   MAC address filter (AP mode)    802.1x   IEEE802.1x Authenticator    Station isolation    Management    Firmware Upgrade   Upgrading firmware via web browser, setting are reserved after upgrade    Reset & Backup   Reset to factory default. User can export all setting into a file via WEB    Ping & Trace Route   Built‐in PING function & Trace Route function in Web GUI    MIB   MIB I, MIB II(RFC1213), Private MIB    SNMP   V1, V2c      1.2 Package Contents  Open  the  package  carefully,  and make sure  that  none  of  the  items listed  below  are missing.  Do not ...
  • Page 8 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 established and removed.  The ability to access real‐time information  Doctors/nurses,  point‐of‐sale employees,  and  warehouse  workers can access  real‐time  information while dealing with patients, serving customers and processing information.  d) Frequently changed environments  Show  rooms,  meeting  rooms,  retail  stores,  and  manufacturing  sites  where  frequently  rearrange the workplace.  e) Small Office and Home Office (SOHO) networks  SOHO users need a cost‐effective, easy and quick installation of a small network.  Wireless extensions to Ethernet networks  Network  managers  in  dynamic  environments  can  minimize  the  overhead  caused  by ...
  • Page 9: Understanding The Hardware

    2 Understanding the Hardware    2.1  Hardware Installation  1. Place the unit in an appropriate location after conducting a site survey.  2. Plug  one end  of the  Ethernet  cable  into  the Network port  of  the PoE  injector  and another  end  into your PC/Notebook.   3. Plug one end of another Ethernet cable to AP/Bridge port of the PoE injector and the other end  into you cable/DSL modem (Internet)  4. Insert the DC‐inlet of the power adapter into the 24V port of the PoE injector and the other end  into the power socket on the wall.     This diagram depicts the hardware configuration                       2.2   Hardware Description  ...
  • Page 10: Mounting Kits

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   2.3  Mounting Kits  The images below depict the standard mounting kits.       Pole Mount Wall Mount Window Mount                                    ...
  • Page 11 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   2. Select Internet Protocol (TCP/IP) and then click on the Properties button. This will allow you to  configure the TCP/IP settings of your PC/Notebook.                                      3. Select Use the following IP Address radio button and then enter the IP address and subnet mask.  Ensure that the IP address and subnet mask are on the same subnet as the device.   For Example:          ...
  • Page 12: Switching Between Operating Modes

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 3 Switching Between Operating Modes    This device can operate in three modes: Access Point, Client Bridge, WDS Bridge and Client Router.  This chapter will describe how to switch between operating modes.      3.1 Logging In  To  configure  the  device  through  the  web‐browser,  enter  the  IP  address  of  the  device  (default:  192.168.1.1) into the address bar of the web‐browser and press Enter.   Make  sure  that  the  device  and  your  computer  are  configured  on  the  same  subnet.  (Refer  to ...
  • Page 13: Access Point Operating Mode

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   4 Access Point Operating Mode    Logging In     To  configure  the  device  through  the  web‐browser,  enter  the  IP  address  of  the  device  (default:  192.168.1.1) into the address bar of the web‐browser and press Enter.   Make  sure  that  the  device  and  your  computers  are  configured  on  the  same  subnet.  Refer  to ...
  • Page 14: Status

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Status      Click  on  the  Status  link  on  the  navigation  drop‐down  menu.  You  will  then  see  three  options:  Main,  Wireless  Client  List,  and System Log. Each option is described in detail below.         4.2.1 Main  Click  on  the  Main  link  under  the  Status  drop‐down  menu.  The  status  that  is  displayed ...
  • Page 15: Wireless Client List

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 4.2.2 Wireless Client List  Click on the Wireless Client List link under the Status drop‐down menu. This page displays the list  of Clients that are associated to the Access Point.   The MAC addresses and signal strength for each client is displayed. Click on the Refresh button to  refresh the client list .          4.2.3 System Log   Click  on  the  System  Log  link  under  the  Status  drop‐down  menu.  The  device  automatically  logs  (records)  events  of  possible  interest  in  its  internal  memory.  If  there  is  not  enough  internal ...
  • Page 16: System Properties

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   4.3.1 System Properties   Click on the System Properties link under the System drop‐down menu. This page allows you to  switch  the  operating  mode  of  the  device,  as  well  as  specify  a  name  and  select  the  operating  region.       Device Name: Specify a name for the device (this is not the SSID),  Country/Region: Select a country from the drop‐down list.  Operating  Mode:  Select  and  operating  mode.  Configuration  for  each  operating  mode  is ...
  • Page 17: Spanning Tree Settings

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     4.3.3 Spanning Tree Settings  Click on the Spanning Tree link under the System drop‐down menu Spanning‐Tree Protocol is a  link management protocol that provides path redundancy while preventing undesirable loops in  the network.        Spanning Tree Status: Choose to enable or disable the spanning tree feature.    Bridge Hello Time: Specify the number of seconds for the hello time.   Bridge Max Age: Specify the number of seconds for the max age.   Bridge Forward Delay: Specify the number of seconds for the bridge forward delay.   Priority: Specify the number of seconds for the priority.   Click on the Apply button to save the changes.        4.4 Wireless  Click  on  the  Wireless  link  on  the  navigation  drop‐down ...
  • Page 18 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   Wireless  Mode:  Depending  on  the  type  of  wireless  clients  that  are  connected  to  the  network,  you may select B, G or B/G‐mixed. If you are not sure about which clients will be accessing the  wireless networks, it is recommended that you select B/G‐mixed for the best performance.    Channel / Frequency: Select a channel from the drop‐down list. The channels available are based  on the country’s regulation.   Current Profiles: User can setup SSID configuration in this item. EOC1650 supports 4 SSIDs, user  can decide to use how many SSID via “Enable” or not. When click “Edit” button, you can setup  detail, include SSID, VLAN ID and Security Mode.                         Wireless Security – Security Mode : WEP   ...
  • Page 19 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0    Security Mode: Select WEP from the drop‐down list if your wireless network uses WEP  encryption. WEP is an acronym for Wired Equivalent Privacy, and is a security protocol that  provides the same level of security for wireless networks as for a wired network.    Authentication  Type:  Select  an  authentication  method.  Options  available  are  Open  Key,  Shared  Key.  An  open  system  allows  any  client  to  authenticate  as  long  as  it  conforms  to  any ...
  • Page 20 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0    Security Mode: Select WPA‐PSK, WPA2‐PSK, or WPA‐PSK Mixed from the drop‐down list if  your wireless network uses WPA pre‐shared key.    Encryption:  Select  TKIP  or  AES  from  the  drop‐down  list  if  your  wireless  network  uses  this  encryption. WPA (Wi‐Fi Protected Access) was designed to improve upon the security features  of  WEP  (Wired  Equivalent  Privacy).  The  technology  is  designed  to  work  with  existing  Wi‐Fi ...
  • Page 21: Wireless Mac Filter

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0      Security Mode: Select WPA, WPA2 or WPA Mixed from the drop‐down list if your wireless  network uses WPA. WPA (Wi‐Fi Protected Access) was designed to improve upon the security  features of WEP (Wired Equivalent Privacy). The technology is designed to work with existing  Wi‐Fi products that have been enabled with WEP. WPA provides improved data encryption  through the Temporal Integrity Protocol (TKIP), which scrambles the keys using a hashing  algorithm and by adding an integrity checking feature which makes sure that keys haven’t been  tampered with.    Encryption:  Select  TKIP  or  AES  from  the  drop‐down  list  if  your  wireless  network  uses  this  encryption.   RADIUS Server: Enter the IP address of the RADIUS server.    RADIUS Port: Enter the port number of the RADIUS server. The default is usually 1812.   RADIUS Secret: Enter the shared password of the RADIUS server.    Group Key Update Interval: Specify the number of seconds after which the Access Point will ...
  • Page 22: Wds Link Settings

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   ACL  (Access  Control)  Mode:  You  may  choose  to  Disable,  Allow  Listed,  or  Deny  Listed  MAC  addresses  from  associating  with  the  network.  By  selecting  Allow  MAC  in  the  List,  only  the ...
  • Page 23 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     Data  Rate: If you  would  like  to force a  data  rate,  you may  select one  from the  drop‐down list.  However, for best performance it is recommended to use the Auto setting.   Transmit  Power:  You  may  have  the  different  application  distance  of  the  device  by  selecting  a  value from the drop‐down list. This feature can be helpful in restricting the coverage area of the ...
  • Page 24: Management

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Management     Click  on  the  Management  link  on  the  navigation  drop‐ down  menu.  You  will  then  see  seven  options:  administration,  SNMP  settings,  backup/restore  settings,  firmware  upgrade, time settings, and  log.  Each option  is  described below.  ...
  • Page 25: Snmp Settings

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Name: Specify a user name into the first field.  Password:  Specify  a  password  into  this  field  and  then  re‐type  the  password  into  the  Confirm  Password field.   Click on the Apply button to save the changes.     4.5.3 SNMP Settings  Click on the SNMP Settings link under the Management menu. This option allows you to assign  the  contact  details,  location,  and  community  name  and  trap  settings  for  SNMP.  This  is  a ...
  • Page 26: Firmware Upgrade

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     Save a copy of the current settings: Click on the Backup button to save the current configuration.   Restore saved settings from a file: Once a file has been backed up, you may restore it by clicking  on the Browse button to select the file, and then the Restore button.    Revert  to  factory  default  settings:  Click  on  the  Factory  Default  Settings  button  to  reset  the  device  to  the  default  settings.  Please  wait  while  the  device  restart  and  then  access  the  device ...
  • Page 27: Log

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0       Manually Set Date and Time: Specify the date and time  Automatically Get Date and Time: Select the time zone from the drop down list and then specify  the IP address of the NTP server.   Click on the Apply button to save the changes.        4.5.7 Log  Click on the Log link under the Management menu. The Log page displays a list of events that are  triggered  on  the  Ethernet  and  Wireless  interface.  This  log  can  be  referred  when  an  unknown  error  occurs  on  the  system  or  when  a  report  needs  to  be  sent  to  the  technical  support ...
  • Page 28 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0                           Ping  Test  Parameters  :  User  can  input  Target  IP,  Ping  Size  and  Ping  Quantity  of  other  network  device which connected you want. And then you can find the ping condition after click Start Ping.  Traceroute Test Parameters: This function help user to monitor a network trace. User can input  IP or domain name on Traceroute target.  ...
  • Page 29: Client Bridge Operating Mode

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   5 Client Bridge Operating Mode    Logging In      To  configure  the  device  through  the  web‐browser,  enter  the  IP  address  of  the  device  (default:  192.168.1.1) into the address bar of the web‐browser and press Enter.   Make  sure  that  the  device  and  your  computers  are  configured  on  the  same  subnet.  Refer  to ...
  • Page 30: Status

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Status       Click  on  the  Status  link  on  the  navigation  drop‐down  menu. You will then see three options: Main, Connection  Status, and System Log. Each option is described in detail  below.       5.2.1 Main  Click  on  the  Main  link  under  the  Status  drop‐down  menu.  The  status  that  is  displayed ...
  • Page 31: System Log

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0       5.2.3 System Log   Click  on  the  System  Log  link  under  the  Status  drop‐down  menu.  The  device  automatically  logs  (records)  events  of  possible  interest  in  its  internal  memory.  If  there  is  not  enough  internal ...
  • Page 32: System

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   System       Click  on  the  System  link  on  the  navigation  drop‐down  menu.  You  will  then  see  three  options:  System  Properties, IP Settings, and Spanning Tree Settings. Each  option is described in detail below.       5.3.1 System Properties   Click on the System Properties link under the System drop‐down menu. This page allows you to  switch  the  operating  mode  of  the  device,  as  well  as  specify  a  name  and  select  the  operating ...
  • Page 33: Spanning Tree Settings

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 device  to  use  a  static  IP  address.  In  this  case,  you  would  be  required  to  specify  an  IP  address,  subnet mask, and default gateway IP address.  IP Address: Specify an IP address  IP Subnet Mask: Specify the subnet mask for the IP address  Default Gateway: Specify the IP address of the default gateway.  Click on the Apply button to save the changes.        5.3.3 Spanning Tree Settings  Click on the Spanning Tree link under the System drop‐down menu Spanning‐Tree Protocol is a ...
  • Page 34: Wireless Security

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     Wireless  Mode:  Depending  on  the  type  of  wireless  clients  that  are  connected  to  the  network,  you may select B, G, or B/G‐mixed. If you are not sure about which clients will be accessing the  wireless networks, it is recommended that you select B/G‐mixed for the best performance.    SSID: The SSID is a unique named shared amongst all the points of the wireless network. The SSID  must be identical on all points of the wireless network and cannot exceed 32 characters. You may  specify an SSID or select one from the Site Survey.  Site  Survey:  Click  on  the  Site  Survey  button  in  order  to  scan  the  2.4GHz  frequency  for  devices ...
  • Page 35 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   Security  Mode:  Select  WEP  from  the  drop‐down  list  if  your  wireless  network  uses  WEP  encryption.  WEP  is  an  acronym  for  Wired  Equivalent  Privacy,  and  is  a  security  protocol  that ...
  • Page 36: Wireless Advanced Settings

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   Encryption:  Select  TKIP  or  AES  from  the  drop‐down  list  if  your  wireless  network  uses  this  encryption. WPA (Wi‐Fi Protected Access) was designed to improve upon the security features of  WEP (Wired Equivalent Privacy). The technology is designed to work with existing Wi‐Fi products  that  have  been  enabled  with  WEP.  WPA  provides  improved  data  encryption  through  the ...
  • Page 37: Management

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     Data  Rate: If you  would  like  to force a  data  rate,  you may  select one  from the  drop‐down list.  However, for best performance it is recommended to use the Auto setting.   Transmit  Power:  You  may  have  the  different  application  distance  of  the  device  by  selecting  a  value from the drop‐down list. This feature can be helpful in restricting the coverage area of the ...
  • Page 38: Snmp Settings

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   Name: Specify a user name into the first field.  Password:  Specify  a  password  into  this  field  and  then  re‐type  the  password  into  the  Confirm  Password field.   Click on the Apply button to save the changes.        5.5.2 SNMP Settings  Click on the SNMP Settings link under the Management menu. This option allows you to assign  the  contact  details,  location,  and  community  name  and  trap  settings  for  SNMP.  This  is  a ...
  • Page 39: Backup/Restore Settings, Reset To Factory Default Settings

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 5.5.3 Backup/Restore settings, Reset to factory default settings  Click  on  the  Backup/Restore  Setting  link  under  the  Management  menu.  This  option  is  used  to  save the current settings of the device in a file on your local disk or load settings on to the device  from  a  local  disk.  This  feature  is  very  handy  for  administrators  who  have  several  devices  that ...
  • Page 40: Time Settings

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 5.5.5 Time Settings  Click on the Time Settings link under the Management menu. This page allows you to configure  the time on the device. You may do this manually or by connecting to a NTP server.     Manually Set Date and Time: Specify the date and time  Automatically Get Date and Time: Select the time zone from the drop down list and then specify  the IP address of the NTP server.   Click on the Apply button to save the changes.        5.5.6 Log  Click on the Log link under the Management menu. The Log page displays a list of events that are  triggered  on  the  Ethernet  and  Wireless  interface.  This  log  can  be  referred  when  an  unknown ...
  • Page 41 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0                    Ping  Test  Parameters  :  User  can  input  Target  IP,  Ping  Size  and  Ping  Quantity  of  other  network  device which connected you want. And then you can find the ping condition after click Start Ping.  Traceroute Test Parameters: This function help user to monitor a network trace. User can input  IP or domain name on Traceroute target.  ...
  • Page 42: Wds Bridge Operating Mode

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 6 WDS Bridge Operating Mode      6.1  Logging In  To  configure  the  device  through  the  web‐browser,  enter  the  IP  address  of  the  device  (default: 192.168.1.1) into the address bar of the web‐browser and press Enter.   Make sure that the device and your computers are configured on the same subnet. Refer to  Chapter 2 in order to configure the IP address of your computer.   After connecting to the IP  address, the  web‐browser  will display the login page.   Specify admin for both the user name and password.   ...
  • Page 43: Status

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 6.2  Status  Click  on  the  Status  link  on  the  navigation  drop‐down  menu.  You  will  then  see  three  options:  Main,  WDS  Link Status, and System Log. Each option is described  in detail below.       6.2.1 Main  Click  on  the  Main  link  under  the  Status  drop‐down  menu.  The  status  that  is  displayed ...
  • Page 44: Wds Link Status

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 6.2.2 WDS Link Status  Click on the WDS Link Status link under the Status drop‐down menu. This page displays the  current  status  of  the  WDS  Link,  including  Station  ID,  MAC  address,  Status,  RSSI(Received  Signal Strength Indicator).           6.2.3 System Log   Click  on  the  System  Log  link  under  the  Status  drop‐down  menu.  The  device  automatically ...
  • Page 45: System

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   6.3   System   Click on the System link on the navigation drop‐down  menu. You will then see System Properties, IP Settings  and Spanning Tree Settings.        6.3.1 System Properties   Click  on  the  System  Properties  link  under  the  System  drop‐down  menu.  This  page  allows  you  to  switch  the  operating  mode  of  the  device,  as  well  as  specify  a  name  and  select  the ...
  • Page 46: Spanning Tree Settings

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 IP  Network  Setting:  Select  Obtain  an  IP  address  automatically  (DHCP) radio button if the  Access  Point  is  connected  to  a  DHCP  server.  This  will  allow  the  Access  Point  to  pass  IP  addresses  to  the  clients  associated  with  it.  You  may  select  Specify  an  IP  Address  radio ...
  • Page 47: Wireless Network

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 6.4.1 Wireless Network  The Wireless Network page allows you to configure the wireless mode, channel, SSID, and  security settings.      Wireless  Mode:  Depending  on  the  type  of  wireless  clients  that  are  connected  to  the  network, you may select B, G or B/G‐mixed. If you are not sure about which clients will be  accessing the wireless networks, it is recommended that you select B/G‐mixed for the best  performance.  Channel/Frequency:  Select  a  channel  from  the  drop‐down  list.  The  channels  available  are ...
  • Page 48: Wds Security

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   MAC Address: you can input the MAC address of WDS device, which you want to link.  Mode:  Enable to connect, and Disable to disconnect.  Click on the Apply button to save the changes.       6.4.3 WDS Security      Security  Mode:  Select  WEP  from  the  drop‐down  list  if  your  wireless  network  uses  WEP  encryption. WEP is an acronym for Wired Equivalent Privacy, and is a security protocol that  provides the same level of security for wireless networks as for a wired network.         WEP Key: Select a key format from the drop‐down list. 64bit‐hex keys require 10 characters, ...
  • Page 49: Management

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     Data Rate: If you would like to force a data rate, you may select one from the drop‐down list.  However, for best performance it is recommended to use the Auto setting.   Transmit Power: You may have the different application distance of the device by selecting  a value from the drop‐down list. This feature can be helpful in restricting the coverage area  of the wireless network.   Fragment  Length:  Packets  over  the  specified  size  will  be  fragmented  in  order  to  improve  performance on noisy networks.  RTS/CTS  Threshold:  Packets  over  the  specified  size  will  use  the  RTS/CTS  mechanism  to ...
  • Page 50: Administration

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 6.5.1 Administration  Click  on  the  Administration  link  under  the  Management  menu.  This  option  allows  you  to  create  a  user  name  and  password  for  the  device.  By  default,  this  device  is  configured ...
  • Page 51: Backup/Restore Settings, Reset To Factory Default Settings

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Read‐Only  Community  Name:  Specify  the  password  for  access  the  SNMP  community  for  read only access.   Read‐Write  Community  Name:  Specify  the  password  for  access  to  the  SNMP  community  with read/write access.   Trap  Destination  IP  Address:  Specify  the  IP  address  of  the  computer  that  will  receive  the ...
  • Page 52: Time Settings

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     Click on the Browse button and then select the appropriate firmware and then click on the  Upgrade button.   Note:  The  upgrade  process  may  take  about  1  minute  to  complete.  Do  not  power  off  the  device during this process as it may crash the device and make it unusable. The device will  restart automatically once the upgrade is complete.       6.5.5 Time Settings  Click  on  the  Time  Settings  link  under  the  Management  menu.  This  page  allows  you  to ...
  • Page 53: Diagnostics

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     Syslog: Choose to enable or disable the system log.  Log Server IP Address: Specify the IP address of the server that will receive the system log.   Local Log: Choose to enable or disable the local log.  Click on the Apply button to save the changes.       6.5.7 Diagnostics  Click on the Diagnostics link under the Management menu. In this page, user can let unit to  ping other network equipment. And user also can monitor a route from unit to your target.               Ping  Test  Parameters  :  User  can  input  Target  IP,  Ping  Size  and  Ping  Quantity  of  other ...
  • Page 54: Client Router Operating Mode

    7 Client Router Operating Mode    7.1  Logging In  To  configure  the  device  through  the  web‐browser,  enter  the  IP  address  of  the  device  (default: 192.168.1.1) into the address bar of the web‐browser and press Enter.   Make sure that the device and your computers are configured on the same subnet. Refer to  Chapter 2 in order to configure the IP address of your computer.   After  connecting  to  the  IP  address,  the  web‐browser  will display the login page.   Specify admin for both the user name and password.    After logging in you will graphical user interface (GUI) of  the  device.  The  navigation  drop‐down  menu  on  left  is  divided into four sections: ...
  • Page 55: Main

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Click  on  the  Status  link  on  the  navigation  drop‐down  menu.  You  will  then  see  four  options:  Main,  DHCP  Client Table, Connection Status and System Log. Each  option is described in detail below.           7.2.1 Main  Click  on  the  Main  link  under  the  Status  drop‐down  menu.  The  status  that  is  displayed ...
  • Page 56: Dhcp Client Table

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0       7.2.2 DHCP Client Table  Click  on the  DHCP  Client  Table link  under  the  Status drop‐down  menu.  This page displays  the current status of all DHCP clients, including IP and expires information.           7.2.3 Connection Status  Click on the Connection Status link under the Status drop-down menu. This page...
  • Page 57: System Log

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 7.2.4 System Log  Click on the System Log link under the Status drop-down menu. The device automatically logs (records) events of possible interest in its internal memory. If there is not enough internal memory for all events, logs of older events are deleted, but...
  • Page 58: System

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   7.3   System   Click on the System link on the navigation drop‐down  menu.  You  will  then  see  System  Properties  setting,  which is described below.         7.3.1 System Properties   Click  on  the  System  Properties  link  under  the  System  drop‐down  menu.  This  page  allows ...
  • Page 59: Wan - Dhcp

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   7.4.1.1 WAN ‐ DHCP  The  WAN  interface  can  be  configured  as  a  DHCP  Client  in  which  the  ISP  provides  the  IP  address to the device. This is also known as Dynamic IP.        Internet Connection Type: Select the DHCP from the drop‐down list.  Account Name: Specify an account name if your ISP has provided you with one.  Domain Name: Specify a domain name if the ISP has provided you with one.     MTU:  The  Maximum  Transmission  Unit  (MTU)  is  a  parameter  that  determines  the  largest ...
  • Page 60: Wan - Ppp O E

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     Internet Connection Type: Select the Static IP from the drop‐down list.  Account Name: Specify an account name if your ISP has provided you with one.  Domain Name: Specify a domain name if the ISP has provided you with one.     MTU:  The  Maximum  Transmission  Unit  (MTU)  is  a  parameter  that  determines  the  largest  packet  size  (in  bytes)  that  the  router  will  send  to  the  WAN.  If  LAN  devices  send  larger ...
  • Page 61 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     Internet Connection Type: Select PPPoE from the drop‐down list.      MTU:  The  Maximum  Transmission  Unit  (MTU)  is  a  parameter  that  determines  the  largest  packet  size  (in  bytes)  that  the  router  will  send  to  the  WAN.  If  LAN  devices  send  larger ...
  • Page 62: Wan - Pptp

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 7.4.1.4 WAN – PPTP    The WAN interface can be configured as PPTP. This type of connection is usually used for a  DSL service and requires a username and password to connect.      Internet Connection Type: Select PPPoE from the drop‐down list.      MTU:  The  Maximum  Transmission  Unit  (MTU)  is  a  parameter  that  determines  the  largest  packet  size  (in  bytes)  that  the  router  will  send  to  the  WAN.  If  LAN  devices  send  larger ...
  • Page 63: Lan Settings

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 interface and click the Connect button manually any time that you wish to connect to the  Internet.   Domain  Name  Service:  Select  Get  Automatically  from  ISP  if  the  ISP  will  provide  the  DNS  address,  if  not,  select  Use  these  DNS  servers  and  specify  the  primary  and  secondary  DNS ...
  • Page 64: Wireless

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 L2TP Pass Through: Place a check in this box if you would like to enable this pass through.  Layer  2  Tunneling  Protocol  is  a  transport  protocol  that  enables  tunneling  through  the  Internet for the establishment of virtual private networks.  IPSec Pass Through: Place a check in this box if you would like to enable this pass through.  IPSec is a VPN protocol used to implement secure exchange of packets at the IP layer.   Click on the Apply button to save the changes.       7.5   Wireless  Click on the Wireless link on the navigation drop‐down  menu.  You  will  then  see  three  options:  wireless ...
  • Page 65: Wireless Security

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 7.5.2 Wireless Security      7.5.2.1 Wireless Security : WEP  Security  Mode:  Select  WEP  from  the  drop‐down  list  if  your  wireless  network  uses  WEP  encryption. WEP is an acronym for Wired Equivalent Privacy, and is a security protocol that  provides the same level of security for wireless networks as for a wired network.         Authentication  Type:  Select  an  authentication  method.  Options  available  are  Open  Key, ...
  • Page 66: Wireless Security : Wpa-Psk, Wpa2-Psk

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Default  Key:  You may use up to four different keys for four different networks.  Select the  current key that will be used.   Key 1‐4: You may enter four different WEP keys.   Click on the Apply button to save the changes.         7.5.2.2 Wireless Security : WPA‐PSK, WPA2‐PSK,   Security  Mode:  Select  WPA‐PSK  or  WPA2‐PSK  from  the  drop‐down  list  if  your  wireless  network uses WPA pre‐shared key.        Encryption:  Select  TKIP  or  AES  from  the  drop‐down  list  if  your  wireless  network  uses  this ...
  • Page 67: Management

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     Data Rate: If you would like to force a data rate, you may select one from the drop‐down list.  However, for best performance it is recommended to use the Auto setting.   Transmit Power: You may have the different application distance of the device by selecting  a value from the drop‐down list. This feature can be helpful in restricting the coverage area  of the wireless network.   Fragment:  Packets  over  the  specified  size  will  be  fragmented  in  order  to  improve  performance on noisy networks.  RTS Threshold: Packets over the specified size will use the RTS/CTS mechanism to maintain  performance  in  noisy  networks  and  preventing  hidden  nodes  from  degrading  the ...
  • Page 68: Administration

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 7.6.1 Administration  Click  on  the  Administration  link  under  the  Management  menu.  This  option  allows  you  to  create  a  user  name  and  password  for  the  device.  By  default,  this  device  is  configured ...
  • Page 69: Backup/Restore Settings, Reset To Factory Default Settings

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0     SNMP Enable/Disable: Choose to enable or disable the SNMP feature.  Contact: Specify the contact details of the device.  Location: Specify the location of the device.  Read‐Only  Community  Name:  Specify  the  password  for  access  the  SNMP  community  for  read only access.   Read‐Write  Community  Name:  Specify  the  password  for  access  to  the  SNMP  community ...
  • Page 70: Firmware Upgrade

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Restore  saved  settings  from  a  file: Once a  file has been backed up, you may restore it by  clicking on the Browse button to select the file, and then the Restore button.    Revert to factory default settings: Click on the Factory Default Settings button to reset the  device  to  the  default  settings.  Please  wait  while  the  device  restart  and  then  access  the  device using the default IP address: 192.168.1.1        7.6.4 Firmware Upgrade ...
  • Page 71: Log

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0 Manually Set Date and Time: Specify the date and time  Automatically  Get Date  and  Time: Select the time zone from the drop down list and then  specify the IP address of the NTP server.   Click on the Apply button to save the changes.       7.6.6 Log  Click  on the Log link under  the  Management menu.  The Log  page  displays  a  list of  events  that are triggered on the Ethernet and Wireless interface. This log can be referred when an  unknown  error  occurs  on  the  system  or  when  a  report  needs  to  be  sent  to  the  technical ...
  • Page 72 EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   Ping  Test  Parameters  :  User  can  input  Target  IP,  Ping  Size  and  Ping  Quantity  of  other  network device which connected you want. And then you can find the ping condition after  click Start Ping.  Traceroute  Test  Parameters: This function help user to monitor a network trace. User can  input IP or domain name on Traceroute target.   ...
  • Page 73: Appendix A - Fcc Interference Statement

    EnGenius EOC1650 Wireless Access Point / Client Bridge Version 2.0   Appendix A – FCC Interference Statement    Federal Communication Commission Interference Statement    This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  B  digital  device,  pursuant  to  Part  15  of  the  FCC  Rules.    These  limits  are  designed  to  provide  reasonable  protection ...
  • Page 74: Appendix B - Ic Statement

    Multi-Function Gigabit Wireless-N Client Bridge Version 1.0 Appendix B – IC Statement      Industry Canada statement:    This device complies with RSS‐210 of the Industry Canada Rules. Operation is subject to the following  two conditions:   (1) This device may not cause harmful interference, and (2) this device must accept any interference  received, including interference that may cause undesired operation.    IMPORTANT NOTE:  Radiation Exposure Statement:   This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment.  This equipment should be installed and operated with minimum distance 20cm between the radiator  & your body.    This device has been designed to operate with an antenna having a maximum gain of 5 dBi. Antenna  having  a  higher  gain  is  strictly  prohibited  per  regulations  of  Industry  Canada.  The  required  antenna  impedance is 50 ohms.

Table of Contents