Use the following guidelines to help you ensure a proper ION installation:
■ DO NOT use tubing with less than a 180 PSI rating.
■ DO NOT connect copper tubing to the elbow fitting, shutoff valve,
or directly to the ION. If copper tubing is used it may result in a
catastrophic leak. If building code or regulations require copper tubing,
contact Natural Choice Technical Support for specific instructions and
recommendations for adapter fittings.
■ Make sure there are no sharp bends or kinks in the tubing. Allow extra
tubing to prevent stress on the fittings. Avoid tubing contact with other
objects and sharp edges.
■ All tubing used in the elbow fitting and shutoff valve must be clean, cut
square with a sharp knife or razor, and free of nicks and burrs.
■ If you need additional tubing, make sure it is ¼ inch OD and meets
ANSI/NSF and FDA standards for drinking water. DO NOT use tubing
of an unknown quality or origin.
NOTE: The ION is programmed with an energy saving feature called SleepMode.
This feature uses a light sensor. When the area is dark (i.e. evening and weekends),
SleepMode automatically turns off the cooling system, and also reduces the hot water
temperature on ION's with hot water.
If you place the ION in an area with (1) low light, or (2) motion sensors, or (3) where
the lights are turned ON/OFF frequently, you can program the ION to disable
SleepMode feature.
This can be done by visiting our website or calling Natural Choice for Technical
Support.