Advertisement

Vax V-047 10th.qxd
PLEASE NOTE: The white material in the HEPA filter will
discolour over time -This is NORMAL and will NOT affect
the performance of the filter.
WARNING: Always empty the dirt container and clean
the HEPA filter before each use and during prolonged
usage. Never over fill the dirt container, remove dirt and
clean the HEPA filter each time the dirt container is
emptied during prolonged usage or risk motor damage.

Cleaning the Pre-Motor Filter

Underneath the dirt container is a pre-motor filter. If
found to be defective, please replace (Fig.6/6).
Fig.6/6
Cleaning the Dirt Container
WARNING: To reduce the risk of electric shock, the
power cord must be disconnected before removing
the dirt container, HEPA filter, changing the filters or
performing maintenance/troubleshooting checks.
• The dirt container can be washed in lukewarm
water (max 40ºC) (Fig.6/7).
• Do not use strong detergents.
• Ensure that the dirt container is fully dry before
putting back on the vacuum cleaner. Do not wash
in dishwasher.
Fig.6/7
3/10/05
4:14 PM
Page 7
Dirt Container & Filter: Removal & Replacement/Maintenance

7. Maintenance

Motor Thermostat
Important: This unit is equipped with a motor
protection thermostat. If for some reason the
vacuum cleaner should overheat, the thermostat will
automatically turn the unit off. Should this occur:
• Push the on/off switch once.
• Disconnect the plug from the electrical outlet.
• Check the source of overheating problem. (i.e.
clogged hose or filter).
• If clogged hose or filter is found, unclog the hose
and replace the filters.
• Wait at least one (1) hour before attempting to re-
use the vacuum.
• After unit has cooled down for one (1) hour, plug in
the cleaner and push the on/off switch. The
vacuum should start again.
• If the vacuum still does not start, contact Vax Care
0870 606 1248.

Cleaning and Changing the Belt

TOOLS REQUIRED: Phillips screwdriver.
WARNING: To reduce the risk of electric shock, the
power cord must be disconnected before removing
the dirt container, HEPA filter, changing the filters or
performing maintenance/troubleshooting checks.
Occasionally, the power nozzle drive belt will require
changing, the frequency will depend upon the amount
of vacuum use.
1. Turn vacuum off and unplug from power supply.
Press handle release button and lay vacuum
cleaner on a flat, level surface.
2. Using a Phillips screwdriver, remove the four (4)
screws on the underside of the cleaner (Fig.7/1)
to release the top cover of the vacuum head
(Fig.7/2).
Fig.7/1