S p e c i f i c a t i o n s
15

Specifications

TruePower
Power (W)
Continuous Power
Surge Power
Output Waveform
AC Output voltage
AC Output amps (up to)
DC Input Voltage
DC Input Amps (up to)
Efficiency
No load current
Cooling Fan
Short Protection
Soft- Start
High Voltage Protection
Low Battery Alarm (Bat' Saver)
Low Battery Shutdown (Bat' Saver)
Low battery Alarm
Low Battery Shutdown
Reverse Polarity Protection (By Fuse)
Operating environment temperature
External Fuse
Recommended User Supplied
ABYC E-11 Compliant Fuse
ProMariner Part No. for Recommended
User Supplied ABYC E-11 Compliant Fuse
Amperage
200W
400W
200W
400W
200W
400W
400W
800W
Modified Sine Wave
115V +/- 10%
1.8A
3.6A
10V to 15V +/-.5v
20A
40A
>85%
<0.3A
<0.6A
No
Yes
Yes
Yes
Yes
Yes
11.9VDC
11.7VDC
10.5VDC +/- .5VDC
10VDC +/- .5VDC
Yes
-15 to 50° Celsius or 5 to 122° Fahrenheit
25A
40A
25A
40A
AGU Fuses for TruePower Models
Single Position
AGU Fuse
AGU Fuse
for 200w
for 400w
AGU Fuse Holder
88103
88530
88540
5 - 70 amps
30 amp
40 amp
F e a t u r e s / I n s t a l l a t i o n G u i d e l i n e s

Inverter Features

The TruePower inverter comes standard with a Ground Fault Circuit Interrupter
(GFCI) protected Dual AC outlet which can protect the user against hazardous
electrical shock that could be caused by dampness, water spray, or worn cables.
Bat' Saver- mode allows the user to protect from draining down the entire power of
the engine start battery, and shuts the inverter off when the battery reaches a threshold
of 11.7 volts allowing you to still start your boat or vehicle.
Soft Start, Noise Filtered Technology- progressively increases the output voltage to
start heavy loads, with minimal or no interference.
TruePower performance features include:
- Internal Conformal Coating for Anti-Corrosion
- Soft Start and Noise Filtered Technology
- Bat' Saver Mode – 200 to 1200 watt Models
- True Rated Continuous Power
- Hi-Surge Ratings for Demanding Loads
- Heavy Duty Marine/Industrial Construction
- Constructed to UL 458
- Meets the Requirements of ABYC E-11 Marine
- Highly Visible Power & Fault LED Indicators
TruePower Inverters are protected by a variety of features including:
- GFCI AC Outlet Safety Protected
- Input Polarity Protection
- Low Battery Alarm
- Low Battery Shutdown
- Overload Protection
- Output Short Circuit Protection
- Thermal Protection
- Over Voltage (15 VDC) Protection
Note: These inverters may not be suitable for use with some fluorescent lighting, halogen lights or
other inductive loads. If you wish to run such an item, plug it in to one of the inverter outlets and plug
in a small non-inductive load bearing item such as a low wattage light bulb into the other outlet.

Mounting your Inverter

IMPORTANT: ALWAYS PLACE THE INVERTER IN AN ENVIRONMENT WHICH IS:
(A) WELL VENTILATED
(B) NOT EXPOSED TO DIRECT SUNLIGHT OR HEAT SOURCE
(C) OUT OF REACH FROM CHILDREN
(D) AWAY FROM WATER / MOISTURE, OIL OR GREASE
(E) AWAY FROM ANY FLAMMABLE SUBSTANCE
(F) DO NOT INSTALL DIRECTLY ABOVE OR BELOW BATTERIES