S p e c i f i c a t i o n s
15

GENERAL SPECIFICATIONS

AC Receptacle:
Battery Polarity Protect:
DC Fuse (Recommended):
Dimension (L x W x H):
Efficiency:
Output Short Protect:
Output Waveform:
Operating Temperature Range:
Overload Protect:
Storage Temperature Range:
Part Number:
Part Number:
Thermal Protect:
Weight:

ELECTRICAL SPECIFICATIONS

Battery Low Shutdown:
Continue Output Power:
Input Voltage Range:
Input Full Load Current:
No Load Power Draw
Output Frequency:
Output Power:
Output Voltage (At No Load):
Output Voltage (At Full Load):
Peak Output Power:
CAUTION: ALWAYS PLACE THE INVERTER IN AN ENVIRONMENT WHICH IS:
(A)
WELL VENTILATED
(B)
NOT EXPOSED TO DIRECT SUNLIGHT OR HEAT SOURCE
(C)
OUT OF REACH FROM CHILDREN
(D)
AWAY FROM WATER / MOISTURE, OIL OR GREASE
(E)
AWAY FROM ANY FLAMMABLE SUBSTANCE
2 – Dual Three-prong
Yes (Fuse)
70 A
13 x 6.25 x 3.75
88%
Yes (Button Breaker)
Pure Sine Wave (<3% Thd)
32° F – 158° F (0° Fc – 40° C)
Yes
-22° F - 158° F (-30° C – 70° C)
79400 With Outlets
79405 Hardwired
50 +/-5 Deg C
13 Lbs
10.5 VDC
400 W
10.5 – 15.3 VDC
40 A
0.5 A
60 +/- 0.05 Hz
400 Watts
120 Vac Rms +/- 3 V
120 Vac Rms +/- 5 V
1000 Va Surge For 5 Seconds
TRUEPOWER 400PS FEATURES
Figure 1
7
AC SHORE
BREAKER
POWER STATUS
Shore ON
Green: Inverter ON
Red: Inverter Fault
5
2
1. ON / Off Switch turns the inverter to ON or to OFF.
2. Shore Power light illuminates when you are connected to shorepower. (shorepower
refers to the AC input power from a utility grid, generator or external AC source)
3. Inverter / Fault Light illuminates Green when the inverter is operating and
illuminates Red for fault conditions such as over temperature, output overload,
or battery over voltage.
4. Two AC Outputs to power connected appliances.
5. Supplemental Circuit Protection Button may trip if there is an over-current (over
10 amps) or a short circuit.
6. GFCI opening enables the Reset and Test monthly capabilities.
7. Fan (internal) activates when the internal temperature of the inverter increases.
The fan speed varies with the internal temperature and turns off when the inverter
cools down.
2
Figure 2
9
DC Input
8
DC Grounding
Connector
6
1
1. DC Input Cables
2. AC Receptacles
3. AC Input cord for shorepower
4. Wiring box access panel (Top panel)
5. AC Strain Relief for hardwiring
T r u e P o w e r 4 0 0 P S F e a t u r e s
6
4
POWER
3
1
4
AC Output
Remote
AC Input
5
7
3
6. Chassis ground lug
7. Remote control jack
8. Mounting flanges (Side panel)
9. Ventilation openings provides
air circulation (Side panel)
4