9. Amplifier Installation

9.1 Unpacking

Carefully open the shipping carton and check for any damage to the device or the supplied accessories. Every
Turbosound product is tested and inspected before leaving the factory and should arrive in perfect condition. If any
damage is discovered, please notify the shipping company immediately. Only the consignee may initiate a claim
with the carrier or their insurers for damage incurred during shipping. Save the carton and packing materials for the
carrier's inspection.
In addition to the 20000DP amplifier, the shipping carton include the following items:
20000DP Quick Start & Field Reference Guide
AC mains lead (power cable) with Neutrik® powerCON® connector
Rear brackets for additional rack support (pair) along with associated mounting hardware
Software Installer and Documentation CD-ROM
Please keep the original carton and associated packaging to facilitate shipping of the device should the need arise.

9.2 Mounting

Airflow for cooling the 20000DP is from front panel (intake) to rear panel (exit). Please ensure that no object, such as
rack doors or lids are placed at the front or rear of the rack to ensure that airflow is maximized. This device has no
top or bottom vents and therefore may be stacked directly on top of each other. Sufficient space should be available
at the front of the rack to accommodate the handles, and at the rear to accommodate connectors and cables;
allowance must be made for cable or loom bends within a rack.

9.3 Rear Mounting

Two rear support brackets along with associated mounting hardware are included with the 20000DP, as shown in
Figure 1; it is recommended that these are used wherever possible. Fit the brackets to the vertical rails at the rear of
the rack. Figure 2 and Figure 3 show the fitting options for fixed and removable installation. The support brackets
are reversible and may be fitted to point either to the front or rear of the rack; the orientation used depends on the
rack depth and position of the rear rack rails. Two mounting methods are possible; note that the method shown in
Figure 2 additionally provides extra security against unauthorized removal. For situations where rapid removal and
replacement is required, the method shown in Figure 3 should be used.