Advertisement

Code, CSA C22.1, if an external electrical source is utilized. This
appliance is equipped with a three-prong [grounding] plug for
your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do
not cut or remove the grounding prong from this plug. For an
ungrounded receptacle, an adapter, which has two prongs and a
wire for grounding, can be purchased, plugged into the ungrounded
receptacle and its wire connected to the receptacle mounting screws.
With this wire completing the ground, the appliance cord plug can
be plugged into the adapter and be electrically grounded.
CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.
WARNING:
Unplugging of blower accessory will not stop the heater
from cycling. To shut heater off:
1. Turn temperature dial or thermostat to lowest setting.
2. Turn knob on gas control to "OFF", depressing slightly.
Do not force.
Cleaning
The blower wheel will collect lint and could require cleaning once
a year. If the air output decreases or the noise level increases, it
indicates a dirty wheel. Complete removal of the wheel and scrub-
bing it with a brush under flowing water is recommended.
Oiling
The blower motor has an oil hole located on each end of the motor.
Use #20 motor oil only. It is best to oil the motor several times
during the heating season using 2 or 3 drops each time. If the mo-
tor fails to start and hums, it could be a tight bearing due to lack of
oil. This may be corrected by pouring kerosene in the oil holes,
allowing to stand for a few hours and then oiling properly.
12821-8-0907
Parts List
Index
Part
Description
No.
No.
1
R-2090
Motor
2
632016
Motor Cushion
3
RH-036
Motor Support
4
642030
Blower Wheel
5
RH-710
Blower Housing Assembly
6
9120106
Fan Control Switch
7
872087
Heyco Bushing
8
DV-806
Switch Box
9
DV-807
Switch Box Cover
10
R-2091
Wire Assembly 19" (483mm)
11
8720161
Heyco Bushing
12
R-2099
Cord Set 72" (183cm)