Trane R410a Owner's Manual page 23

Inverter interactive air conditioner
Hide thumbs Also See for R410a:
Table of Contents

Advertisement

Error
Error Description
codes
0x0E
Outdoor discharge
temperature sensor
error
0x0F
Outdoor EEPROM
parameter reading
error
0x13
IPM module failure
0x14
High/ Low Voltage
protection
0x17
Compressor position
protection
0x1A
Outdoor Condenser
coil temperature
sensor error
23
Error Displayed on
Remote
Error 14: Outdoor
discharge temperature
sensor error -- Please
Contact Customer Care
Error 15 : Outdoor
EEPROM parameter
reading error -- Please
Contact Customer Care
Error 19: IPM module
failure -- Please Contact
Customer Care
Error 20 :High/ Low
Voltage protection --
Please Contact Customer
Care
Error 23:Compressor
position protection --
Please Contact Customer
Care
Error 26: Outdoor
Condenser coil
temperature error --
Please Contact Customer
Care
Unit Response
Cool mode or Dry
mode:
Unit will run with
Compressor OFF.
Fan mode:
Run IDU as per user
settings. "
Cool mode or Dry
mode:
Unit will run with
Compressor OFF.
Fan mode:
Run IDU as per user
settings. "
Cool mode or Dry
mode:
Unit will run with
Compressor OFF.
Fan mode:
Run IDU as per user
settings. "
Cool mode or Dry
mode:
Unit will run with
Compressor OFF.
Fan mode:
Run IDU as per user
settings. "
Cool mode or Dry
mode:
Unit will run with
Compressor OFF.
Fan mode:
Run IDU as per user
settings. "
Cool mode or Dry
mode:
Unit will run with
Compressor OFF.
Fan mode:
Run IDU as per user
settings. "
Action to be
Taken by user
Contact
Customer Care
Contact
Customer Care
Contact
Customer Care
Contact
Customer Care
Contact
Customer Care
Contact
Customer Care
48663967 Rev 1