Maintenance

Flush the Spray Gun

Flush the gun before changing colors, at the end of the
day, before storing, and before repairing the gun.
WARNING
Fire, Explosion, and Electric Shock Hazard
To reduce the risk of fire, explosion, or elec-
tric shock, turn the ES ON/OFF valve OFF
before flushing the gun.
CAUTION
Flush the gun with a non-conductive, compatible
solvent. Conductive solvents can cause the gun to
malfunction.
Do not use methylene chloride as a flushing or
cleaning solvent with this gun as it will damage
nylon components.
1. Turn the ES ON/OFF valve OFF.
309291P
Refer to the gun operation manual
(supplied) for Daily Care and Cleaning
procedures.
INSTRUCTIONS
ES
I
O
ti1273a
WARNING
Pressurized Equipment Hazard
To reduce the risk of an injury, follow the
Pressure Relief Procedure on page 23
whenever you are instructed to relieve the
pressure.
2. Relieve the pressure.
3. Change the fluid source to solvent, or disconnect
the fluid line and connect a solvent supply line to the
gun.
4. Point the gun into a grounded metal pail. Flush until
clean solvent flows from the gun.
5. Relieve the pressure.
Maintenance
ti1276a
ti1276a
ti1276a