U S E R M A N U A L
DMX512 Input
DMX512 Output
AMX192 Output
AMX192 Input
Reset switch
Indicator LEDs
DMX512 termination switch
Adjustment pots
DIP switches
Number switches
AC power cable
TM
Converter
The Response ConverterTM network interface allows you to convert 192 DMX512 signals
to AMX192 or 192 AMX192 signals to DMX512. The compact interface box features an
optically isolated DMX512 link and a 100 hertz output update rate. This manual provides
information on all Response Converter controls, connectors and indicators.
1 1
To use Response Converter, follow these steps:
1. Plug power cable into a 120 VAC outlet.
2. For DMX512 to AMX192 operation, set DIP switch 3 down and switch 4 up. If optical
isolation is desired, set DIP switch 1 up. For AMX192 to DMX512 operation, set DIP
switch 1 down, switch 3 up and switch 4 up.
3. Press Reset.
4. Insert input and output cables into appropriate connectors.
5. Set number switches to starting dimmer output number (see page 2).
6. If Response Converter is the last device in a DMX512 data link, set DMX512
terminator switch On (right). In AMX192 to DMX512 mode, leave terminator switch Off
(left).
7. See following pages for adjustment pot settings and additional information on switch
functions and settings.
Note: When data flow is interrupted, all outputs fade to zero percent after three minutes.
1
2
3
4
5
6
7
8
1 1

Advertisement

loading

Summary of Contents for ETC REsponse

  • Page 1 5. Set number switches to starting dimmer output number (see page 2). 6. If Response Converter is the last device in a DMX512 data link, set DMX512 terminator switch On (right). In AMX192 to DMX512 mode, leave terminator switch Off (left).
  • Page 2 DMX512 to AMX192 operation. For AMX192 to DMX512 operation, enter a starting number between 001 and 192. The Response Converter reads numbers over the output quantity limit as a starting address of 1. You do not have to press Reset when resetting the starting address, unless you are also ending a diagnostic test.
  • Page 3: Reset Switch

    Bottom LED continuous Receiving power DMX512 termination switch Set the termination switch On (right) if the Response Converter is the last device in a DMX512 data stream. If you are sending a DMX512 data stream to another interface or dimming device, set the termination switch Off (left). For AMX192 to DMX512 operation, set terminator switch Off (left).
  • Page 4: Dip Switch Settings

    Optical isolation disabled (AMX192 to DMX512) Down AC power The Response Converter has an operating range of 90 to 140 volts with optimal performance at 110 volts. It has an internal type GMA-1/2 fuse. Disconnect power before replacing fuse. Specifications Dimensions 2.25"H x 6"W x 7"D...