Harman Stove Company Accentra Installation & Operating Manual page 17

Pellet stove
Hide thumbs Also See for Accentra:
Table of Contents

Advertisement

3 ft.
Fig.25
to combustibles
3 ft.
Fig.26
to combustibles
venting
This method provides excellent venting for normal
operation and allows the stove to be installed closest
to the wall. Two and a half inches from the wall is safe;
however, three inches allows better access to remove
the rear panel. The vertical portion of the vent should be
three to five feet high. This vertical section will provide
natural draft in the event of a power failure. Note: do
not place joints within wall pass-throughs.
3 ft.
to combustibles
combustibles
This method also provides excellent venting for
normal operation but requires the stove to be installed
farther from the wall. The vertical portion of the vent
should be three to five feet high and at least three inches
from a combustible wall. This vertical section will provide
natural draft in the event of a power failure. Note: do
not place joints within wall pass-throughs.
3 ft.
to combustibles
combustibles
KEEP COmbuSTIblES (SuCh AS
grASS, lEAvES, ETC.) AT lEAST 3
FEET AwAY FrOm ThE FluE OuTlET
ON ThE OuTSIdE OF ThE buIldINg.
#1 Preferred method
#2 Preferred method
CAuTION
17