Engineers technical data

OVERALL DIMENSIONS
Width:
580 mm.
Depth:
500 mm.
Height:
8 mm.
CUT OUT DIMENSIONS
Width:
550 mm.
Depth:
470 mm.
Thickness: 30 mm.
Ignition HT Spark
Spark Generator
Ispra Control's BF 50066 - 230-240V 0.6 YA T 120
Spark Gap
Fixed
Rear Left Burner (semi-rapid)
Heat Input
2.0 kW (6824 BTU/HR)
Front Left Burner (rapid)
Heat Input 3.0 kW (10236 BTU/HR)
Characteristics
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
NOZZLE REFERENCE
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
NOZZLE REFERENCE
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
Semi-rapid
Rapid
Aeration adjustment none
8
BURNER
RAPID
(large)
POSITION
MAX
kW
3.0
m
3
/h
0.286
119
1/100 mm
kW
2.8
g/h
202
8 6
1/100 mm
28
32
40
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable.
Rear Right Burner (semi-rapid)
Heat Input
Front Right Burner (auxiliary)
Heat Input 1.0 kW (3412 BTU/HR)
SEMI-RAPID
AUXILIARY
(medium)
MIN
MAX
MIN
MAX
0.65
2.0
0.45
1.0
0.062
0.190
0.043
0.095
Adjust.
9 6
Adjust.
7 0
0.65
2.0
0.45
1.0
4 7
144
3 2
7 2
4 0
7 1
3 2
5 0
APPLIANCE CLASS: 3
APPLIANCE CATEGORY: II2H3+
APPLIANCE GAS SUPPLY:
Natural gas G20 / 20mbar
2.0 kW (6824 BTU/HR)
(small)
MIN
0.33
0.031
Adjust.
0.33
2 4
2 8