Bosch GWH 715 ES Installation Instructions Manual page 37

Temperature modulated with electronic ignition suitable for heating potable water only - not approved for space heating purposes (intended for variable flow applications)
Hide thumbs Also See for GWH 715 ES:
Table of Contents

Advertisement

intake and exhaust may cause unstable burner flames
and noise.
5. Lack of adequate gas pressure. Inadequate gas
pressure will cause the fuel-to-air mixture (CO
out of adjustment. This will result in unstable burner
flames and noise. Ensure gas pressure is in
accordance with specifications in section 3.12, page
24 Measuring Gas Pressure. A gas pressure reading
is needed to proceed further. Contact your original
installer or a local certified gas technician to obtain
this reading.
6. Verify proper CO
readings per chapter 6.4, page
2
30. CO
adjustments must be done by a certified
2
gas technician with a calibrated combustion gas
analyzer.
6 720 608 158
) to be
2
Troubleshooting