INSTALLATION INSTRUCTIONS
ROOF OR WALL VENTILATOR
MODEL DHG6003UC & DHG1003UC
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
IMPORTANT: Save these instructions for the Local Electrical Inspector's use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
SAFETY WARNING: Before servic-
ing or cleaning unit, switch power off
at the service panel and lock service
disconnecting means to prevent
power from being switched on acci-
dentally. When the service discon-
necting means cannot be locked, at-
tach a tag to the service panel to
indicate power has been switched off
for maintenance.
WARNING - TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OB-
SERVE THE FOLLOWING:
Recommended for use only over conventional domestic gas and electric ranges, and
INSTALLATION:
1. Remove and discard shipping bracket (attached to motor
mounts and inlet collar). Check to see if blower wheel turns
freely. Do not replace top until installation is complete.
2. Provide a square cutout through the roof (or wall) as shown
by the dashed lines, or cut a round hole to fit duct with a
separate hole for electrical conduit as shown by solid lines
in Fig. 1.
3. Install the remote ventilator with the discharge pointing
down slope as shown in Figures 3 and 4. Follow standard
roofing procedures. Install the ventilator so the discharge
edge is on top of the shingles and the rear edge is
underneath the shingles.
NOTE: The unit must be sealed between the roof (or wall)
and the underside of the flange with roofing mastic to
prevent leaks. For installation on a flat roof, or roofs with
a pitch less than 1-1/2" in 12", install ventilator on the curb
as shown in Fig. 2. Position the curb on flat roofs so that
the discharge (low) end points away from prevailing wind.
4. Connect ventilator to the exhaust system with 8 inch diam.
duct for DHG6003UC and 10" diam. duct for DHG1003UC
and use adjustable elbow to adjust to roof angle. Tape all
joints to prevent air leaks.
5. Connect ducting in the inlet to the ventilator with duct tape.
6. Clearance to combustible material is 0".
OWNER: Please retain these instructions for future reference.
A. Installation work and electrical wir-
ing
person(s) in accordance with all ap-
plicable codes & standards, including
fire-rated construction.
B. Sufficient air is needed for proper
combustion and exhausting of gases
through the flue (chimney) of fuel
burning equipment to prevent back
drafting. Follow the heating equip-
ment manufacturers guideline and
safety standards such as those pub-
lished by the National Fire Protection
Association (NFPA), and the Ameri-
can Society for Heating, Refrigera-
tion and Air Conditioning Engineers
use with an approved Bosch Hood.
must be done by qualified
For wiring to all approved Bosch products, see Installation
Instructions provided with that product.
ONCE INSTALLATION AND WIRING ARE COMPLETE:
1. Turn ventilator on High for 5 minutes to ensure proper
installation.
2. Step to Medium & Low ensuring each speed setting.
3. Turn ventilator off.
Fig. 1 TOP VIEW Down Slope of Roof or Wall
Model
DHG6003UC 5-11/16"
DHG1003UC 7-1/4"
(ASHRAE), and the local code au-
thorities.
C. When cutting or drilling into wall or
ceiling, do not damage electrical wir-
ing and other hidden utilities.
D. To properly exhaust air, be sure to
duct air out side. Do not vent exhaust
air into spaces within walls, ceilings,
attics, crawl spaces, or garages.
WARNING: To reduce the risk of
fire, use only metal ductwork.
CAUTION - For General Ventilating
Use Only. Do Not Use To Exhaust
Hazardous Or Explosive Materials And
Vapors.
Dimension
A
B
C
6-1/8"
9"
6-15/16" 11"
(Over)

Advertisement

loading

Summary of Contents for Bosch DHG1003UC

  • Page 1 (low) end points away from prevailing wind. 4. Connect ventilator to the exhaust system with 8 inch diam. duct for DHG6003UC and 10" diam. duct for DHG1003UC Dimension and use adjustable elbow to adjust to roof angle. Tape all Model joints to prevent air leaks.
  • Page 2 Figure 3 Figure 2 CURB FOR ROOF Figure 4 Figure 5 Figure 6 – Remote Blower Dimensions TYPICAL INSTALLATION USING BOSCH HOODS MODEL DHG6003UC 8" Dia. 8" Dia. 10-3/8 11-1/2 4-5/8 14-7/8 8-3/4 3-1/2 DHG1003UG 10" Dia. 10" Dia. 10-3/4...
  • Page 3 Trou tuyau de 8 po de diamètre pour le DHG6003UC et un tuyau de 10 po de diamètre pour le DHG1003UC. Utiliser le coude réglable pour régler selon l’angle du toit. Mettre du ruban sur tous les joints pour éviter les fuites d’air.
  • Page 4 Figure 3 Figure 4 Figure 2 BORDURE POUR TOIT Figure 6 – Dimensions soufflerie télécommandée Figure 5 INSTALLATION TYPIQUE UTILISANT LES HOTTES BOSCH MODÈLE DHG6003UC 8 po Dia. 8 po Dia. 10 3/8 11 1/2 4 5/8 14 7/8 8 3/4 3 1/2 DHG1003UG 10 po Dia.10 po Dia.
  • Page 5 Conecte el ventilador al sistema de escape con un ducto con diámetro de 8 pulg. para DHG6003UC y un ducto con diámetro de 10" para DHG1003UC y use un codo ajustable Dimensiones para ajustarse al ángulo del techo. Ponga cinta en todas las Modelo juntas para evitar fugas de aire.
  • Page 6 Transición Pared Exterior Figura 5 Figura 6 – Dimensiones del Ventilador Remoto A = Codo Cinta Conducto Conducto con Diá. 8" INSTALACIÓN TÍPICA USANDO CAMPANAS DE BOSCH MODELO DHG6003UC 8" Diá. 8" Dia. 10-3/8 11-1/2 4-5/8 14-7/8 8-3/4 3-1/2 DHG1003UG 10" Diá. 10" Dia. 10-3/4...
  • Page 8 BSH reserves the right to change specifications or design without notice. Some models are certified for use in Canada. BSH is not responsible for products which are transported from the United States for use in Canada. Check with your local Canadian distributor or dealer.

This manual is also suitable for:

Dhg6003uc