AEG 1300 D Operating And Installation Manual
AEG 1300 D Operating And Installation Manual

AEG 1300 D Operating And Installation Manual

Cooker hood

Advertisement

Quick Links

1300 D
Dunstabzugshaube
Afzuigkap
Hotte aspirante
Cooker Hood
Campana extractora
Exaustor
Montage- und Gebrauchsanweisung
Installatie- en gebruksaanwijzing
Manuel de montage et d'utilisation
Operating and Installation Instructions
Instrucciones de montaje y manejo
Manual de Instruções

Advertisement

Table of Contents
loading

Summary of Contents for AEG 1300 D

  • Page 1 1300 D Dunstabzugshaube Afzuigkap Hotte aspirante Cooker Hood Campana extractora Exaustor Montage- und Gebrauchsanweisung Installatie- en gebruksaanwijzing Manuel de montage et d’utilisation Operating and Installation Instructions Instrucciones de montaje y manejo Manual de Instruções...
  • Page 2: Table Of Contents

    Maintenance and care Metal grease filter Carbon filter Changing the light bulb Cleaning Special accessories Technical assistance service Guarantee conditions Service Technic Details Installation Electrical connection Wall unit mounting Wall mounting Printed on recycled paper AEG - putting words into action...
  • Page 3: Safety Warnings

    Safety warnings for user • Always cover lighted elements, to prevent excess heat from damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames. • Also, when frying, keep the deep frying pan on the cooker top/ cooker under careful control.
  • Page 4 • The national decree on fuel-burning systems specifies a maximum depression of 0.04 bar in such rooms. • The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circum- stances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.
  • Page 5: Introduction

    (special accessory). • You will need original AEG activated carbon filter for this function (see Special Accessories). • The unit features two outlet holes, one of which A is located on the top of the unit while the other B is located on the rear.
  • Page 6: Hood Operation

    Hood Operation • The hood is fitted with a variable speed motor. The most effective use of the hood is obtained by switching it on a few minutes before you start cooking and leaving it on a for approximately 15 minutes after you have finished, thus ensuring all cooking odours are eliminated.
  • Page 7: Maintenance And Care

    Maintenance and care • The hood must always be disconnected from the mains power supply before beginning any maintenance work. Metal grease filter • The purpose of the grease filters is to aspirate grease particles which form during cooking and it must always be used, either in the external evacuation or internal recycling function.
  • Page 8: Carbon Filter

    • The activated carbon filter should only be used if you want to use the hood in its filtering function. • To do this you will need an original AEG activated carbon filter (see special accessories). • Cleaning/replacing the carbon filter Unlike other carbon filters, the LONGLIFE carbon filter can be cleaned and reactivated.
  • Page 9: Changing The Light Bulb

    Warning • Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard. You are therefore strongly recommended to follow these instructions. • The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations.
  • Page 10: Guarantee Conditions

    Guarantee conditions Guarantee Conditions AEG offer the following guarantee to the first purchaser of this appliance. 1. The guarantee is valid for 12 months commencing when the appliance is handed over to the first retail purchaser, which must be verified by purchase invoice or similar documentation.The guarantee does not...
  • Page 11 Before you move please contact your nearest Customer Care Centre, listed below, to give them details of your new home.They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Senlis +33 (0) 44 62 29 29...
  • Page 12: Technic Details

    Technic Details Dimensions: Height x Width x Depht (in cm) 16,3 x 59,9 x 53,5 Maximum absorbed power: 200 W Motor absorption: 120 W Lighting: 2 x 40 W Length of the cable: 115 cm Electrical connection Safety warnings for the electrician Before connecting the appliance to the power supply, check that the voltage indicated on the rating plate corresponds to the mains power supply available.
  • Page 13: Wall Unit Mounting

    Wall unit mounting - Fig. 6 • Make the holes on the bottom of the cupboard (2), using the drilling template (1). Provide an hole also for exhausting pipe (4) ONLY if is decided to use the hood in Exhausting version (3). •...
  • Page 14: Installation

    Wall mounting - Fig. 7 • Sign a centerline onto the wall (1). Fit the template onto the wall (2). • Fix the drilling template to the wall. • Make 3 Ø 8mm holes in the wall (3), 2 at upper points, 1 as desired at lower points.