UP Arrow/DOWN Arrow ................3 Other Pushbuttons ................... 3 DISPLAY/COUNTER ................3 DISPLAY MESSAGE EXPLANATION ............. 3 INPUTS TO THE DIGITAL GATEWAY ........... 4 LIMIT SWITCHES—TERMINALS 8 AND 9 ..........4 Open (LSO) ....................4 Close (LSC) ....................4 PB1 (PUSHBUTTON)—TERMINAL 11 ........... 4 ALTERNATE ACTION INPUTS (A/A MOMENTARY CONTACT ACTIVATORS)—TERMINAL 12 ........
Page 4
PAGE LOOP—TERMINAL 29, THREE TERMINAL PLUG ........ 6 PRIORITY OF INPUTS ................6 TIMERS ....................7 OPEN BACKUP TIMER ................7 CLOSE BACKUP TIMER ................7 ALTERNATE ACTION (A/A) CLOSE DELAY TIMER....... 7 AUTO CLOSE DELAY TIMER ..............8 SETTING THE TIMERS ................8 START-UP PROCEDURES ..............
Page 5
Close Jog ....................14 Open Jog ....................14 Reverse Delay .................... 14 Loop Call Delay ..................14 PROGRAM 5, REVERSE INPUT LOGIC ..........14 PROGRAM 6 .................... 14 SETTING THE PROGRAM OPTIONS ............. 15 REPLACING MODELS DG1000 AND DG1100 WITH DG1215 ....16...
HOW TO USE MANUAL HOW TO USE MANUAL Throughout this manual, the following key words are used to alert the reader of potential hazardous situa- tions, or situations where additional information for successfully performing the procedure is presented: WARNING is used to indicate the potential for personal injury, if the procedure is not performed as described.
INTRODUCTION INTRODUCTION MODEL DG1215 on page 16 for replacement proce- dures.) It provides connections for multiple activators, ® The DG1215 is a direct replacement for Rytec’s close delay timers, back-up timers, and status indica- Digital Gateway ® model DG1000 and DG1100. (See tors.
The open jog/reset button will operate while the left side of the unit. The power, output, and input the Digital Gateway is in the AJAr or EdGE alarm connections to the Digital Gateway are made through condition. (See Figure 1.) this terminal strip.
INPUTS TO THE DIGITAL GATEWAY INPUTS TO THE DIGITAL GATEWAY PB1 (PUSHBUTTON)—TERMINAL 11 (N.O. CONTACT) The pushbutton on the control box is connected here. Pushing the button (a momentary connection) while the door is closed, closing or stopped between limits will open the door.
(LSC on) and the Reversing Edge LED will blink. the Digital Gateway will be idle. The message LOC will be on the display and no inputs will be active. Remov- To reset the system: Re-establish the connection,...
PROGRAM 3—TERMINAL 26 (N.C. CONTACT) PRIORITY OF INPUTS This input has various functions that are explained in Various inputs to the Digital Gateway have priority over the programming section of this manual. (See OP- other inputs. The following paragraphs explain how TIONAL PROGRAMS on page 13.)
To reset the system: Determine the reason the door LED "ON" did not reach the limit switch and correct the problem. Then reset the Digital Gateway by pressing the Open Jog/Reset button or Stop button. This timer should be set 1–2 seconds longer than it takes the door to open.
(See always on. Settings and messages for this timer will be INPUTS TO THE DIGITAL GATEWAY on page 4 displayed as "dEL =" plus time. for a description of the various inputs to the Digital Gateway.)
ALARM CONDITIONS ALARM CONDITIONS COnnECt, MISSING CONNECTIONS The Digital Gateway monitors the N.C. inputs on power up. This alarm indicates one or more of the OP = 0 required N.C. inputs are missing. The LED(s) for the missing input(s) and the display message COnnECt will blink.
A0500029 Figure 11 EdGE, REVERSING EDGE This alarm indicates that the reversing edge connec- tion (input 17) is missing. The Digital Gateway moni- A0500029 tors the connection every time the door is fully open. If Figure 10 the connection is missing for 2 seconds or more, the...
NON-ALARM CONDITIONS NON-ALARM CONDITIONS HELLO, SAFE START-UP When power is applied to the Digital Gateway the door will not move regardless of the status of any activator. EdGE The display will read HELLO. The system will reset and be operational with any activator change or if the Digital Gateway is reset with the Open Jog/Reset button or Stop input (Figure13).
OUTPUTS 4. Install the replacement and reconnect the plug-in The 3 triac outputs of the Digital Gateway share a terminal blocks, making sure the numbers on the common power source which is terminal 4. Terminal 4 terminal blocks correspond with the terminal is internally connected to the 115 vac power source.
Activating this input again will close the door. If the A/A Close Delay timer This input can be used to place the Digital Gateway is on when the door is opened with input 24, the door into an inactive condition, operate the door manually or will open until the Passage timer reaches zero.
Reverse Delay, rdt = 00 When this option is turned on PROGRAM 3, INPUT The Digital Gateway is programmed to immediately 26—Passage Limit Switch, LSP will also be turned on. reverse the door if an activator or safety input is These two options allow you to open the door partially operated while the door is closing.
SETTING THE PROGRAM OPTIONS SETTING THE PROGRAM OPTIONS As described in OPTIONAL PROGRAMS on page 13, there are 6 program menus and their submenus available. You will use the UP and DOWN arrows, the Set button (A/A Close Delay) and the Select button (Auto Close Delay) to select and set the program options which will be shown on the display.
Page 22
REPLACING MODELS DG1000 AND DG1100 WITH MODEL DG1215 4. After you find the program you wish to change, press the Set button to enter the sub-menu for that particular program. Each sub-menu will be identi- fied by the program number and an option code.
Page 23
Digital Gateway. These will be used to set up the replacement DG1215. 7. To use the AJAr alarm message on the DG1215 the breakaway bottom bar kill switches must be 2. Turn off power to the door.