Electrical Connections

Before connecting the appliance, check that the voltage quoted on the
rating plate - that is, the nominal voltage of the appliance - corre-
sponds to the available mains voltage. The rating plate can be found on
the lower housing of the ceramic glass hob.
The mains connection must be carried out by an expert electrician. The
VDE-regulations and the valid prescriptions by the local power suppy
boards have to be compiled with.
Prior to connection it should be checked whether the voltage stated on
the rating plate - i.e. the nominal voltage of the appliance and of the
oven/control box - is identical with the prevailing mains voltage. The
rating plate is located on the lower housing of the hob.
The heating element voltage amounts to 230 V ~. The appliance will
also perfectly perform with the former mains voltage of 220 V ~.
The mains connection must be carried out in a way that an all-pole
insulating device is existing with a contact opening of at least 3 mm,
e.g. LS-automatism, earth-leakage circuit-breaker or fuse.
A wire of type H05VV-F or of higher rating is to be used as supply cable.
The mains terminal is located in the bottom of the appliance behind a
covering slide. It can be opened with a screw driver (pict.).
According to existing mains voltage the appliance has to be connected
in correspondence with the diagrams of connecting possibilities. The
bridges of the terminal board are to be changed accordingly, if need be.
The protective conductor is to be connected to terminal x. The pro-
tective conductor must be longer than live leads.
The cable connections have to be connected as shown and the
terminal screws be firmly tightened.
Afterwards the supply cable has to be secured by strain relief device
and the covering slide must be closed by firmly pressing down until it
engages.
Prior to first use remove any existing labels and protective film from
the ceramic glass plate or the frame of the hob.
After connecting the electrical supply, all cooking zones should be
1
briefly switched on one after the other at their maximum power, in
order to test whether they are operational.