Safety Stops; Recommended Safety Stops; Mandatory Safety Stops - Suunto Vyper Air User Manual

Hide thumbs Also See for Vyper Air:
Table of Contents

Advertisement

Table 5.7. RGBM model settings
RGBM setting
100%
50%

5.10. Safety Stops

Safety Stops are widely considered good diving practice for recreational diving, and are
an integral part of most dive tables. The reasons for performing a Safety Stop include:
reducing sub-clinical DCI, microbubble reduction, ascent control, and orientation before
surfacing.
The Suunto Vyper
Stop and Mandatory Safety Stop.

5.10.1. Recommended Safety Stops

With every dive over 10 meters, there is a three minute countdown for the Recommended
Safety Stop, to be taken in the 6 - 3 m/10 ft - 20 ft range. This is shown with the STOP
sign and a three-minute countdown in the center window instead of the no-decompression
time.
NOTE

5.10.2. Mandatory Safety Stops

When the ascent rate exceeds 10 m/33 ft per minute continuously for more than 5 seconds,
the microbubble build-up is predicted to be more than is allowed for in the decompression
model. The Suunto RGBM calculation model responds to this by adding a Mandatory
Safety Stop to the dive. The time of this Mandatory Safety Stop depends on the severity
of the ascent rate excess.
The STOP sign appears in the display and when you reach the depth zone between 6 m
and 3 m/20 ft and 10 ft, the CEILING label, ceiling depth, and the calculated Safety Stop
time also appear in the display. You should wait until the Mandatory Safety Stop warning
disappears.The total length of the Mandatory Safety Stop time depends on the seriousness
of the ascent rate violation.
Desired Tables
Standard Suunto RGBM model
(Default)
Attenuated RGBM model
AIR
displays two different types of Safety Stops: Recommended Safety
WHEN STOP IS DISPLAYED,
MAKE A RECOMMENDED SAFETY
STOP FOR 3 MINUTES.
The Recommended Safety Stop, as the name implies, is
recommended. If it is ignored, there is no penalty applied to the
following surface intervals and dives.
WHEN CEILING AND STOP ARE
DISPLAYED, MAKE A ONE MINUTE
MANDATORY SAFETY STOP IN THE
DEPTH ZONE BETWEEN 6 M AND 3 M.
Effect
Full RGBM effects
Smaller RGBM effects, higher risk!