Quick Reference Tables For Duo 2400 Pack - Bowens DUO 2400 PACK Operating Instructions Manual

Bw-3005
Hide thumbs Also See for DUO 2400 PACK:
Table of Contents

Advertisement

Quick Reference Tables For DUO 2400 Pack

COMBINE MODE - The TOTAL flash output set by the 'POWER' switch and the
'VARIATOR A' is divided EQUALLY between the NUMBER of Flash Heads fitted to
the Pack as shown below:-
POWER
SWITCH
SETTING
2400
1200
600
ISOLATE MODE - The TOTAL flash output is split asymmetrically between the two
Channels dependent upon the 'POWER' switch, 'VARIATOR A' and 'VARIATOR B'
settings as shown below:-
POWER
SWITCH
SETTING
2400
1200
600
NUMBER OF
HEADS
AVAILABLE FROM
FITTED
1
1
2
1
1
2
1
1
2
NUMBER OF
HEADS
AVAILABLE FROM
FITTED
1
1
2
1
1
2
1
1
2
- 14 -
MAX POWER
CHANNEL A
2400W-s
-
1200W-s
1200W-s
-
600W-s
600W-s
-
300W-s
MAX POWER
CHANNEL A
1200W-s
-
1200W-s
600W-s
-
600W-s
300W-s
-
300W-s
MAX POWER
AVAILABLE FROM
CHANNEL B
-
2400W-s
1200W-s
-
1200W-s
600W-s
-
600W-s
300W-s
MAX POWER
AVAILABLE FROM
CHANNEL B
-
1200W-s
1200W-s
-
600W-s
600W-s
-
300W-s
300W-s