Download Print this page

ECH2O Tec. Watermakers 500-PRO-1 Owner's Manual

Pro series vertical system 230v / 50hz reverse osmosis desalination system
Hide thumbs Also See for Watermakers 500-PRO-1:

Advertisement

Quick Links

E E E E
C C C C H H H H
Watermakers
PAGE
2
INTRODUCTION
3
SPECIFICATIONS
4
STANDARD SYSTEM FEATURES
5
INSTALLATION INSTRUCTIONS
6-7
OPERATION INSTRUCTIONS
8
MEMBRANE CLEANING PROCEDURE
9
MAINTENANCE TIMETABLE
10
PRESSURE VESSEL ENDPLUG CHANGING PROCEDURE
11
ELECTRICAL DIAGRAM
12
TROUBLESHOOTING GUIDE
13-14
HIGH PRESSURE PUMP REPAIR INSTRUCTIONS
15-16
LIMITED WARRANTY
O Tec.
O Tec.
2 2 2 2
PRO SERIES
VERTICAL SYSTEM
230V / 50HZ
500-PRO-1 / 900-PRO- 2
1200-PRO- 3 / 1500-PRO- 4
OWNERS MANUAL
O Tec.
O Tec.
TM

Advertisement

loading
Need help?

Need help?

Do you have a question about the Watermakers 500-PRO-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for ECH2O Tec. Watermakers 500-PRO-1

  • Page 1 O Tec. O Tec. O Tec. O Tec. 2 2 2 2 Watermakers PRO SERIES VERTICAL SYSTEM 230V / 50HZ 500-PRO-1 / 900-PRO- 2 1200-PRO- 3 / 1500-PRO- 4 OWNERS MANUAL PAGE INTRODUCTION SPECIFICATIONS STANDARD SYSTEM FEATURES INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS...
  • Page 2 Thank you for choosing an ECHO Tec. reverse osmosis desalination system. We trust that you will be completely satisfied with our product. The Beach House Series has been specially designed for small hotels, marinas and beach houses. The high power efficiency and low maintenance cost makes high quality RO water in many cases more economical than land supplied water, if available.
  • Page 3: Specifications

    SPECIFICATIONS Rated Performance ECHO Tec: 500 – PRO – 1 900 – PRO – 2 1200 – PRO – 3 1500 – PRO – 4 ° ° RO Membrane Type: Salt Rejection: Salinity Range: PH Range: Chlorine Tolerance: Operating Pressure: Feed Water Pressure: Feed Water Temperature Range: °...
  • Page 4 STANDARD SYSTEM FEATURES Fully assembled desalination system...
  • Page 8: Membrane Cleaning Procedure

    CAUTION: The use of chemicals or cleaning methods other than those outlined in the cleaning instructions will void the ECHO Tec. warranty. Nonionic surfactants for membrane cleaning or other chemicals not approved in writing by Echo Marine Ltd. will void the element warranty.
  • Page 9: Maintenance Timetable

    MAINTENANCE TIMETABLE COMPONENT MAINTENANCE TIME INTERVAL REQUIRED INTERMITTENT DUTY...
  • Page 10 MEMBRANE CHANGING PROCEDURE PRESSURE VESSEL END PLUG CHANGING PROCEDURE It is important not to over tighten the product port/s to avoid the end plug to crack.
  • Page 12: Troubleshooting Guide

    HIGH PRESSURE PUMP SYSTEM TROUBLESHOOTING GUIDE MALFUNCTION CAUSE REMEDY The pressure Worn packing seals Replace seals drops broken valve spring Replace spring Fouled inlet strainer Clean strainer Fouled pre-filter(s) Replace filter cartridge(s) Cavitation Check suction lines for restrictions Water in crankcase High humidity Reduce oil change interval Worn seals...