INTRODUCTION
3
SPECIFICATIONS
4
STANDARD SYSTEM FEATURES
5
INSTALLATION INSTRUCTIONS
6-7
OPERATION INSTRUCTIONS
8
MEMBRANE CLEANING PROCEDURE
9
MAINTENANCE TIMETABLE
10
PRESSURE VESSEL ENDPLUG CHANGING PROCEDURE
11
ELECTRICAL DIAGRAM
12
TROUBLESHOOTING GUIDE
13-14
HIGH PRESSURE PUMP REPAIR INSTRUCTIONS
15-16
LIMITED WARRANTY
All manuals and user guides at all-guides.com
2 2 2 2
PRO SERIES
VERTICAL SYSTEM
230V / 50HZ
500-PRO-1 / 900-PRO- 2
1200-PRO- 3 / 1500-PRO- 4
OWNERS MANUAL
O Tec.
O Tec.
O Tec.
O Tec.
TM

Advertisement

Table of Contents
loading

Summary of Contents for ECH2O Tec. PRO Series

  • Page 1 C C C C H H H H O Tec. O Tec. O Tec. O Tec. 2 2 2 2 Watermakers PRO SERIES VERTICAL SYSTEM 230V / 50HZ 500-PRO-1 / 900-PRO- 2 1200-PRO- 3 / 1500-PRO- 4 OWNERS MANUAL PAGE...
  • Page 2 All manuals and user guides at all-guides.com INTRODUCTION Thank you for choosing an ECHO Tec. reverse osmosis desalination system. We trust that you will be completely satisfied with our product. The Beach House Series has been specially designed for small hotels, marinas and beach houses. The high power efficiency and low maintenance cost makes high quality RO water in many cases more economical than land supplied water, if available.
  • Page 3: Specifications

    All manuals and user guides at all-guides.com SPECIFICATIONS Rated Performance min. 20 gallons – 75ltr. / hour ECHO Tec: 500 – PRO – 1 min. 38 gallons – 140ltr. / hour 900 – PRO – 2 min. 50 gallons – 210ltr. / hour 1200 –...
  • Page 4 All manuals and user guides at all-guides.com STANDARD SYSTEM FEATURES Fully assembled desalination system in aluminum vertical flame with shock mounted 316Ti high pressure pump, control panels, RO vessels and 5 and 20 micron cartridge filtration system. 1 Fresh water flush kit with hose and 316SS hose clamps 1 Product water tube 10ft / 3m 1 Reject hose ½”...
  • Page 5: Installation Instructions

    All manuals and user guides at all-guides.com INSTALLATION INSTRUCTIONS Position the desalination system in a cool and dry location. Mount the system using all four mounting holes. The electrical installation should only be done by a professional electrician. Check the correct voltage before installing the system.
  • Page 6: System Shut Down Procedure

    All manuals and user guides at all-guides.com SYSTEM OPERATION INSTRUCTIONS The reverse osmosis membrane contains a preservative solution to prevent microbiological growth. If ingested, may cause irritation of the gastro-intestinal tract, colic, diarrhea, or other similar symptoms. Therefore, discard all the product water for at least thirty minutes of initial operation or after storage before drinking or use in food preparations! Do not operate the system using contaminated feed water sources (oil, chlorine or other chemicals).
  • Page 7 All manuals and user guides at all-guides.com FRESH WATER FLUSH PROCEDURE Caution: The fresh water pressure should not exceed the range of the low pressure gauge/s. The installation of a pressure reducer may be necessary. You should fresh water flush your watermaker after every use or infuse a biocide solution for long term storage.
  • Page 8: Membrane Cleaning Procedure

    All manuals and user guides at all-guides.com MEMBRANE CLEANING PROCEDURE The membranes of the ECHO Tec. Watermaker must be chemically cleaned when the product water output drops by 20% of the specified amount. The frequency of this occurring will vary greatly depending upon feed water. Fouling of the membranes will naturally occur during normal usage of the ECHO Tec.
  • Page 9: Maintenance Timetable

    All manuals and user guides at all-guides.com MAINTENANCE TIMETABLE The following maintenance timetable is an estimate of the time intervals at which maintenance may be required only. This schedule must be adjusted to the regularity of usage, the condition of the intake water, the length of time the system is exposed to seawater and the total running time following each system cleaning.
  • Page 10 All manuals and user guides at all-guides.com MEMBRANE CHANGING PROCEDURE PRESSURE VESSEL END PLUG CHANGING PROCEDURE Remove the product port (if installed) and the high pressure fitting. Remove the two/three M6 bolts. Remove the two/tree locking plates (locks) Remove the backing plate Pull the end plug with the aid of a hand tight inserted product port in one fast pull.
  • Page 11 All manuals and user guides at all-guides.com...
  • Page 12: Troubleshooting Guide

    All manuals and user guides at all-guides.com HIGH PRESSURE PUMP SYSTEM TROUBLESHOOTING GUIDE MALFUNCTION CAUSE REMEDY The pressure Worn packing seals Replace seals drops broken valve spring Replace spring Fouled inlet strainer Clean strainer Fouled pre-filter(s) Replace filter cartridge(s) Cavitation Check suction lines for restrictions Water in crankcase...
  • Page 13 All manuals and user guides at all-guides.com HIGH PRESSURE PUMP REPAIR INSTRUCTION SERIES EP-12-34 / EP-14-34 / EP-17-34 Disassembly sequence of the front end of the ECH O Tec. high-pressure pump. Refer to the pump diagram. Remove the three discharge valve plugs and the three inlet valve plugs (32), with a 22 mm socket wrench.
  • Page 14 All manuals and user guides at all-guides.com Should you find it necessary to service the plunger assembly (16), you can do so by removing the tension screw (16D). Inspect all parts and replace as necessary. NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pump 180 degrees to the desired position.
  • Page 15 All manuals and user guides at all-guides.com...
  • Page 16 All manuals and user guides at all-guides.com ECHO TEC. WATERMAKER LIMITED WARRANTY Echo Marine Ltd. warrants to the original purchaser for a period of twelve (12) months from the date of shipment that the ECHO Tec. watermaker will perform according to specifications. Echo Marine’s liability under this warranty shall be limited to repair or replacement of the ECHO Tec.
  • Page 17 All manuals and user guides at all-guides.com The ECHO Tec. Membrane Element is guaranteed to be cleanable for a minimum of one year from date of shipment, or commissioning of the system by Echo Marine Ltd, provided that cleaning instructions are adhered to and foulant is acid soluble metal hydroxides and calcium carbonates or alkaline soluble organic, inorganic substances and microbiological slimes.

This manual is also suitable for:

500-pro-11200-pro-3900-pro-21500-pro-4

Table of Contents