Replacing Heavy Duty Air Filter
If the engine seems weak or runs unevenly and
the dust load indicator has turned red the air filter
may be clogged. If run with a clogged air filter,
disruption of operation can occur.
Cleaning/replacing the air filter is carried out as
follows:
Only do so when the dust indicator is red.
WARNING!
The engine and the exhaust
system, become very hot
during operation. Risk for
burns if touched.
Allow engine and exhaust
system to cool at least two (2)
minutes.
1.
Unfasten the two metal clamps on the
sides of the air filter cover. Remove the
air filter cover.
2.
Remove the paper filter. Lightly brush or
use mild air pressure to clean.
IMPORTANT INFORMATION
Do not use compressed air to clean the air
filter.
Do not wash the paper filter.
Do not oil the paper filter.
Do not tap filter to clean this could cause
damage to the sealing.
3.
Only remove and replace safety element
after the paper filter has been replaced 3
or 4 times.
4.
Refit the air filter as follows:
Check that the seal on the bottom of the
paper filter is whole.
Mount the safety element in the air filter
housing.
5.
Place the paper filter over the safety
element.
6.
Replace the cover over the air filter
housing. Fasten the two metal clamps
making sure the cover is snapped into
position.
7.
Push top of dust load indicator to reset it.
42-
English
MAINTENANCE
Heavy Duty Filter
Cap Removal
Outer element
Inner element
8019-016
8019-017
8019-018