4
Use a vacuum cleaner or wash the pre-
filter under a running tap. If the pre-filter is
very dirty, use a soft brush to brush away
the dust.
5
Air dry the pre-filter.
6
Put the pre-filter back into the purifier.
Attach all hooks properly to the purifier.
7
To reattach the front panel, insert the
bottom hooks into the bottom of the
purifier first (1). Then, push the panel
against the body of the purifier (2).
8
Plug the air purifier into the power socket
and press the
button to switch on the
purifier.
9
Press and hold the
seconds to reset the filter lifetime.
»
go off.
3s
Note
Make sure that the pre-filter is completely dry. If it is still
wet, bacteria may multiply in it and shorten the lifetime
of the pre-filter.
Make sure that the side with the two projections is
pointing towards you, and that all hooks of the pre-filter
are properly attached to the purifier.
button for 3