Multi-Point (Wide Area) Calibration - DSPeaker Anti-Mode 2.0 Owner's Manual

Audio processor/usb dac with room correction
Hide thumbs Also See for Anti-Mode 2.0:
Table of Contents

Advertisement

calibrating two subwoofers (either stereo or dual-mono) but not in full-range 2.0
mode. You can still use time-alignment and auto-detect for the full-range 2.0
setup by choosing the Auto-detect option. The auto-detection always calculates
compensation to produce the minimum lag, meaning it will only delay the
channel that is "too early" compared to the other, whereas manual adjustment
of the delays allows delaying both channels. This is of course unnecessary for
any systems where all of the audio is going through Anti-Mode 2.0 Dual Core.
➢Press the OK button to proceed to the next dialog.
Now you can select the upper frequency limit of the automatic correction. Using
the arrow buttons, set the upper limit of the correction between 80 and 500Hz.
Bass signals have no directionality at the lowest frequencies, but they get
directional toward the mid-range bass and above. Because of this, Anti-Mode
2.0 Dual Core employs correction of the summed output on lowest frequencies
(where all audio material is essentially monophonic), but the correction
becomes more channel-dependent towards lower mid-range and higher
frequencies. After all it is a different concept to measure either left or right
channels separately, compared to measuring both in-phase (which applies to
the majority of any bass content). All this directionality versus summed (in-
phase) effects are automatically handled by Anti-Mode 2.0 Dual Core controlled
by the selected correction frequency range.
➢After selecting the desired settings, press OK button on the remote to proceed to the
volume level check. From here on, the calibration process is similar to the Typical
calibration described earlier.

7.Multi-point (Wide Area) Calibration

Anti-Mode 2.0 Dual Core features a wide area optimization method which allows for a
larger "sweet spot" to be corrected. Fortunately, wide area algorithm does not require
you to measure dozens of different places around the listening area. In most cases it
should be enough to make the main calibration in the center of the target listening
area, and when it is complete, more points can be added to the calibration data.
➢To perform a multi-point calibration, the first step is to calibrate the device normally,
following either the Typical or Advanced procedure.
➢After the first calibration, you can add more points by choosing the "Multi-point"
option at the Calibration dialog. Place the microphone to one edge of the listening area
and continue calibration.