Genie QuietLift 2040C Operation And Maintenance Manual page 7

Ac powered belt drive
Hide thumbs Also See for QuietLift 2040C:

Advertisement

M
AINTENANCE AND
A
Step 1:
LIGNING
WARNING
THE SAFE-T-BEAM® MUST BE ALIGNED OR THE OPEN-
ER WILL NOT FULLY FUNCTION.
Serious injury or death from a closing garage door may
result because of failure to test the safety reverse system.
Repeat this test monthly and adjust as needed.
The Safe-T-Beam® is an invisible ray of light that travels
across the bottom of the garage door opening (Figure 1). If
an object blocks the beam while the garage door is closing,
the opener will stop, then reverse and fully open the door.
Figure 1 SAFE-T-Beam®
The Safe-T-Beam® indicator lights display the status of
the Safe-T-Beam® system (Figure 2).
Source Red LED
ON = Power On
OFF= Power Off
If OFF, check wire con-
nection at Powerhead.
Check for broken or
shorted wires. Check
for defective source.
Receiver
Sensor
Figure 2 Indicator Lights
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
A
DJUSTMENTS
T
S
-T-B
HE
AFETY
EAMS
NOTE
NOTE
Sensor Green (2 LED's)
BOTH OFF = NoPower
ONE OFF / ONE ON=Misaligned.
ONE ON / ONE BLINKING=Beam
needs better alignment.
BOTH ON = Normal Function,
No Obstruction.
Transmitter
Source
A
Adjusting the beam (Figure 3).
Adjust the source and sensor units until the Green
indicator lights stay on.
®
Be sure to stay out of the path of the beam while
making adjustments.
If one Green indicator light stays off, check for
Dirt on the lens.
Sun shinning into the lens.
A short in the wiring (check staples and
connections at terminals).
Figure 3 Adjusting Beam