  • Page 3: Table Of Contents

    AW 540-190/120 AW 541-190/120 AW 542-120 AW 543-120 Preface 1. Important notes Page 3-4 1.1 For your safety Page 3 1.2 Operating for the first time Page 4 1.3 About use Page 4 Features Page 5 3. Operation Page 6-8 4.
  • Page 4: Preface

    Preface With your new extractor hood, working in the kitchen will be even more fun. The appliance offers you a number of advantages: – a good extraction capacity with low noise values, – a large number of control functions, – optimum illumination of the cooking surface by a dimmable halogen light.
  • Page 5: Important Notes

    1. Important notes For your safety – Do not clean the appliance with a steam cleaning apparatus or with water pressure – Damaged appliances must not be operated. because this poses a risk of short-circuits. – The appliance must only be connected by an –...
  • Page 6: Operating For The First Time

    If the problem has nothing to time. do with the power supply, please contact your specialist dealer or your local Gaggenau after- – Conscientiously read through the operating and sales service. assembly instructions before operating the appliance for the first time.
  • Page 7: Features

    2. Features Ventilation duct 2 Control panel 3 Grease filters 4 Lighting Fig. 2 Installation accessories for exhaust air mode Stainless steel-design ventilation duct: LK 010-012 for ceiling heights of 2.25 - 2.64 m LK 010-022 for ceiling heights of 2.64 - 3.02 m Aluminium-design ventilation duct: 011-012...
  • Page 8: Operation

    3. Operation The AW 540/541-190 is 90 cm wide, and the AW 540/541/542/543-120 is 120 cm wide. Operation of both extractor hoods is identical. After they have been pressed, all functions selection keys except 0 (“Motor off”) are backlit in green.
  • Page 9 Int key for the intensive level should be pressed when browning and frying in an open pan (see Fig. 6). If you have switched on the hood by selecting the intensive level, it will be switched off again automatically after 5 minutes. Fig.
  • Page 10 Special functions: Intensive time: You can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the key and the 1, 2 or 3 key and you can store this setting (see Fig. 9). When delivered, the appliance is set to five minutes, i.e.
  • Page 11: Cleaning And Care

    4. Cleaning and care Cleaning the grease filters The grease filter saturation display F flashes after an operating time of 30 hours to you indicate to you that you should clean the grease filter (see Fig. 3). The grease filters can of course be cleaned at any time, even if the grease filter saturation display has not started to flash.
  • Page 12: Circulating Air Mode

    Cleaning the extractor hood Clean the exterior of your extractor hood with a soft cloth and mild detergent solution. Do not use any strong, caustic or abrasive cleaning agents. Do not use any abrasive sponges or brushes either. Clean the stainless-steel extractor hood (AW 540/AW 542) with stainless steel cleaner.
  • Page 13: Maintenance

    If the power supply is in proper working order, but the appliance is nevertheless not functioning, then please contact your specialist dealer or Gaggenau after-sales service. Specify the appliance type (see rating plate). Repairs must only be carried out by authorised specialists, thus ensuring the safety of the appliance.
  • Page 14: Assembly Instructions

    6. Assembly instructions Technical data 6.2 Installation AW 540/541-190: Weight: 23,5 kg The applicable regulations of the energy supply Dimensions: 898 x 550 mm companies and the regional construction regulations must be observed when installing AW 540/541-120: Weight: 27,5 kg the hood.
  • Page 15 Flexible aluminium pipes, corrosion-protected Installation accessories for circulating air mode sheet metal pipes and exhaust air pipes whose Stainless steel-design ventilation duct: material conforms to fire B1 in accordance with 010-112 for ceiling heights of 2.36 - 2.64 m DIN 4102 can be used. Exhaust air pipes should LK 010-122 for ceiling heights of 2.64 - 3.02 m have a nominal diameter of 150 mm.
  • Page 16 The extraction function is realised by an external used simultaneously. fan module. We recommend the fan modules GB 032-107 or GB 052/053-140 from our Gaggenau range; the extractor's electronic circuitry is optimised for these fan modules. For the electrical connection between the extractor hood and external fan see installation instructions for the external fan.
  • Page 17 Important: before marking the securing holes, make sure that no electricity or water lines or other lines are laid at the drilling points in the wall. Proceed as follows: – From the bottom edge of the hood, mark a center line on the wall.
  • Page 18 – Secure the hood on the wall with the four screws b (Fig. 21). exhaust air mode proceed as follows: – Establish the pipe connection. – Establish the electrical connection. – Stainless steel chimney only (LK 010-012/022): pull the protective film off the chimney’s trims. Note: avoid damaging the sensitive metal surfaces.
  • Page 19: Installation

    circulating air mode use the installation set included with the ventilation ducts LK 010-112/122 und LK 011-112/122. You also need an activated charcoal filter (KF 001-010). Proceed as follows: – Slightly loosen the screws of the retaining bracket for the chimney paneling. Hang the angle pieces onto the screws and tighten the screws.