Generac Power Systems Guardian Elite 05402 Specification Sheet

30 kw 60 hz liquid cooled gas engine generator sets

Advertisement

Standby Power Rating
30 kW 60 Hz
STANDARD EQUIPMENT
All input connections in one single area
High coolant temperature shutdown
Low oil pressure shutdown
Low coolant level automatic shutdown
Overspeed automatic shutdown
Crank timer
Exercise timer
Oil drain extension
Cool flow radiator
Closed coolant recovery system
FEATURES
Innovative design and fully prototype tested
UL 2200 Listed
Solid state frequency compensated
voltage regulator
Dynamic and static battery charger
Sound attenuated acoustically designed enclosure
Whisper-Test
™ for low noise level exercise
Acoustically designed engine cooling system
State of the art digital control system with R-Series
digital control panel
Model Number:
GENERAC 1.6L ENGINE
Transfer Switch is sold separately
UV/Ozone resistant hoses
Watertight state of the art electrical connectors
Mainline circuit breaker
Radiator drain extension
Battery charge alternator
2 Amp static battery charger
Battery rack and battery cables
Fan and belt guards
Isochronous governor
High flow low noise factory engineered exhaust system
Watertight electrical connectors
Rodent proof construction
High efficiency, low distortion Generac designed
alternator
Vibration isolated from mounting base
Matching Generac transfer switches engineered and
tested to work as a system
All components easily accessible for maintenance
Electrostatically applied powder paint
Liquid Cooled
Gas Engine
Generator Sets
05402 (Tan - Steel)
Whisper-Test™
Low Speed Exercise
62 dB(A) at 23 feet
Naturally Aspirated
Gaseous Fueled
UL 2200 Listed

Advertisement

loading

Summary of Contents for Generac Power Systems Guardian Elite 05402

  • Page 1 Standby Power Rating 30 kW 60 Hz STANDARD EQUIPMENT • All input connections in one single area • High coolant temperature shutdown • Low oil pressure shutdown • Low coolant level automatic shutdown • Overspeed automatic shutdown • Crank timer •...
  • Page 2: Engine Specifications

    APPLICATION & ENGINEERING DATA GENERATOR SPECIFICATIONS TYPE ...Synchronous ROTOR INSULATION ... Class F STATOR INSULATION ... Class F TOTAL HARMONIC DISTORTION ... <5% TELEPHONE INTERFERENCE FACTOR (TIF) ...<50 ALTERNATOR OUTPUT LEADS 3 PHASE ... 4 wire BEARINGS ... Sealed Ball COUPLING ...
  • Page 3 STANDBY 30 kW OPERATING DATA KW RATING ENGINE SIZE GENERATOR OUTPUT VOLTAGE/KW - 60Hz 120/240V, single phase, 1.0 pf GENERATOR LOCKED ROTOR KVA AVAILABLE @ VOLTAGE DIP OF 35% ENGINE FUEL CONSUMPTION (Natural Gas) (Propane) Exercise cycle 25% of rated load 50% of rated load 75% of rated load 100% of rated load...
  • Page 4: Installation Layout

    27.4 DOOR MIN. MIN. RIGHT SIDE VIEW FUEL LINE CONNECTION 3/4" NPT FEMALE COUPLING © 2007 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. #6-300 mcm #8-#4 33.5 33.5 CONCRETE BASE FRONT VIEW...

This manual is also suitable for: