Figure 3.4 – Setting the Spark Plug Gap
Sparking can occur if the wire terminal does not
fit firmly on the spark plug terminal end. If nec-
essary, re-form the wire terminal to obtain a
tight fit.
3.6

FUEL FILTER

Remove and replace the fuel filter (Figure 3.5) once
each year or every 400 hours of operation, whichever
comes first. Fuel filter is removed with a 15/16" deep
well socket.
Figure 3.5 – Fuel Filter
3.7

CLEAN SPARK ARRESTOR

The engine exhaust muffler has a spark arrestor
screen. Inspect and clean the screen every 50 hours
of operation or once each year, whichever comes
first.
If using the generator on any forest-covered,
brush-covered or grass-covered unimproved land,
it must equipped with a spark arrestor. The spark
arrestor must be maintained in good condition by
the owner/operator.
POS
FUEL
NEG
NOTE:
Section 3 – Maintenance
Recreational Vehicle Generator
Clean and inspect the spark arrestor as follows:
Remove the screen retaining bracket by removing
the screw.
Slide the spark arrestor screen out from the tail
pipe.
Inspect screen and replace if torn, perforated or
otherwise damaged. DO NOT USE a defective
screen. If screen is not damaged, clean it with com-
mercial solvent.
Replace the screen and the retaining bracket.
Figure 3.6 - Spark Arrestor
TAILPIPE
P/N 0E0683
RETAINING
SCREW P/N 056892
3.8

CLEANING THE GENERATOR

Keep the generator set as clean and dry as possible.
Protect the unit against excessive dust, dirt, corrosive
vapors, road splash, etc. Permitting dirt and mois-
ture to accumulate on generator windings will have
an adverse effect on the insulation resistance of those
windings.
When moisture is allowed to remain in contact with
windings, some of the moisture will be retained in
voids and cracks in the insulation. This causes a
reduced insulation resistance and will eventually
cause problems. Dirt will make the problem worse,
since dirt tends to hold moisture in contact with
windings. Salt (as from sea air) also will worsen the
problem since it tends to absorb moisture from the
air. Salt and moisture, when combined, form a good
electrical conductor which can be damaging to the
generator windings.
Do NOT use a forceful spray of water to clean
the generator. Water will enter the generator
interior and cause problems, and may also con-
taminate the generator fuel system.
SPARK ARRRESTOR