AEG DM8600 Operating And Installation Manual page 15

Table of Contents

Advertisement

• Mark the wall with a centre line, this will aid mounting procedure (1),
position the template so that the mid line printed on the template
matches with the centre line previously signed, the lower side of the
template corresponds to the lower side of the hood once mounted
(2).
• Drill two holes Ø 8mm and fix the support bracket with two wall
plugs and screws (3).
• Hang the hood (4) adjust its position (5-6) and from the inside of the
hood mark one point for definitive fixing (7), remove the hood and
drill a hole Ø 8mm (8), fit a wall plugs, hang the hood again and fix it
definitively with a screw (9).
• Drill two holes Ø 8mm on the upper side close to the ceilling (10), fit
two wall plugs and fix the chimney support with two screws (11).
In case the hood is to be used in filter version, mount the deflector
F on the chimney support with four screws 2,9x6,5 and fit a vent
hose (12 - Not supplied - must be purchased) to connect
deflector to the outlet hole D of the hood.
In case the hood is to be used in extraction mode, then the deflector
must not be mounted and fit a vent hose (12 - Not supplied - must
be purchased) to connect outlet hole D of the hood to the outside.
• Make electrical connection (13), but leave the hood disconnected
from the main circuit board.
• Insert the vapour screen (Not supplied - must be purchased - see
Special Accessories and page 17 on the motor housing and fix it
with four screws M4x35 (14).
• Fix the chimney first up (15a) to the chimney support (15b), then on
the bottom (16a) to the upper side of the frame (16b) using four
screws 2,9x6,5.
• Connect the hood the the main circuit board and check if the hood
works properly.
15

Advertisement

Table of Contents
loading

Table of Contents