Range .................................................Up to 9.1 m (30 ft.) [varies with surrounding temperature]
Sensing Angle.....................................Up to 150°
Sensor Aiming Adjustment Angle .....90°
Electrical Load ...................................See label on fixture for maximum wattage rating
Bulb Type ...........................................E27 Screw Base, Type "A"
Power Requirements . ..........................230 VAC, 50 Hz
Operating Modes ...............................TEST, AUTO, and MANUAL MODE
ON-Timer . .........................................1, 5, 10 minutes
Test Timer . .........................................5 Seconds
Manual Mode Timer . .........................Dusk-to-Dawn
Ingress Protection . ..............................IP23
SYMPTOM
POSSIBLE CAUSE
Light will not come
1. Light switch is turned off.
on.
2. Bulb is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a new installation.
Light comes on in
1. Light control may be installed in a relatively dark
daylight.
2. Light control is in TEST.
Light comes on for
1. Light control may be sensing small animals or automobile
no apparent reason.
2. Sensitivity is set too high.
Light stays on
1. The sensor may be picking up a heat source like an air
continuously.
2. Light control is in Manual mode.
3. Sensitivity is set too high.
Light flashes on
1. Light control is in the TEST mode and warming up.
and off.
2. Heat being reflected from other objects may be affecting
The Chamberlain Group reserves the right to discontinue products and to change specifications at
any time without incurring any obligation to incorporate new features in products previously sold.
201101-01

SPECIFICATIONS

TROUBLESHOOTING GUIDE

location.
traffic.
vent, dryer vent, or brightly painted, heat-reflective
surface.
the sensor.
SOLUTION
1. Turn light switch on.
2. Check bulb and replace if necessary.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Verify wiring is correct.
1. The fixture is operating normally under these
conditions.
2. Set ON-TIME switch to 1, 5, or 10 minutes.
1. Re-aim sensor. Reduce sensitivity.
2. Reduce sensitivity.
1. Re-aim sensor. Reduce sensitivity.
2. Switch to Auto.
3. Reduce sensitivity.
1. Flashing is normal under these conditions.
2. Re-aim sensor. Reduce sensitivity.