Heat Controller Energy Knight B/A-HMC30AS Service Manual page 23

Wall mounted mini - split system air conditioning / heat pump
Table of Contents

Advertisement

10. Cooling or Heating Mode with Sleep Mode Auto Control
• When selecting the Cooling(
operation diagram is as following.
Cooling Mode with the Sleep Mode
• The setting temperature will be automatically raised by 2°F(1°C) 30 minutes later and by 4°F(2°C) 1 hour later.
• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
INTAKE AIR TEMP.
SETTING TEMP. +1°F(0.5°C)
(Compressor ON)
SETTING TEMP. -1°F(-0.5°C)
(Compressor OFF)
INDOOR FAN SPEED
COMPRESSOR
Heating Mode with the Sleep Mode(only Heating Model)
• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
INTAKE AIR TEMP.
SETTING TEMP. +6°F(+3°C)
(Compressor OFF)
SETTING TEMP.
(Compressor ON)
INDOOR FAN SPEED
COMPRESSOR
) or the Heating(
30 minutes
More than
3 minutes
Low
Low
ON
OFF
More than
3 minutes
Med
Low or OFF
ON
OFF
- 23 -
) combined with the Sleep Mode Auto Control(
2°F
(1°C)
More than
3 minutes
Low
Low
ON
OFF
More than
3 minutes
Med
Low or OFF
ON
OFF
), the
30 minutes
Low
ON
More than
3 minutes
Med
Low or OFF
ON
OFF
2°F
(1°C)