Step 6, Connect Electrical; Step 7, Install Duct Covers And Utility Bars - GE Monogram ZXR7510 Installation Instructions Manual

Recirculating accessories for model zv750, vent hood
Table of Contents

Advertisement

6 CONNECT ELECTRICAL
• Verify that power is turned off at the source.
WARNING:
with a ground wire, a ground must be provided by
the installer. When house wiring is aluminum, be
sure to use U.L. approved anti-oxidant compound
and aluminum-to-copper connectors.
• Insert house wiring through strain relief and
tighten.
• Connect white leads to branch circuit white lead.
• Connect black leads to branch circuit black lead.
• Connect green/yellow leads to branch circuit green
lead or bare ground lead.
• Secure all connections with wire nuts on each
electrical connector.
• Push wires into junction box and replace cover.
Be sure wires are not pinched.
Installation Instructions
If house wiring is not 2-wire
7 INSTALL DUCT COVERS AND
UTILITY BARS
• Separate the duct covers supplied with the hood.
• Discard the upper (inner) section.
• Insert the ZXR758 or ZXR7510 duct cover (with
vent holes) into the original lower section. Be sure
that the new duct section is inside the shorter
original section.
Mounting Screw Holes
• Place the decorative duct covers on top of the hood.
• Insert the lower portion of the duct cover into the
impressions on the top of the hood.
• Extend the inner duct upwards to meet the ceiling
and support frame.
• Secure the duct cover to the frame with the 2 small
Phillips screws provided.
• Install the side utility bars as shown with screws
provided.
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Monogram zxr758

Table of Contents