Duct Cover Accessories; Power Supply; Tools And Materials Required; Electrical Supply - GE Monogram ZXR7510 Installation Instructions Manual

Recirculating accessories for model zv750, vent hood
Table of Contents

Advertisement

DUCT COVER ACCESSORIES

A duct cover accessory is required for recirculating
operation. Use this chart to determine which
accessory is required for your ceiling height.
ZV750SY Installation Heights
Actual
Ceiling
* Possible Hood
Height
Installation Height
24-1/2"
7' 11"
25-1/2"
8' 0"
8' 1"
25-1/2" to 26-1/2"
8' 2"
25-1/2" to 27-1/2"
8' 3"
25-1/2" to 28-1/2"
25-1/2" to 29-1/2"
8' 4"
25-1/2" to 30"
8' 5"
8' 6"
25-1/2" to 30"
8' 7"
25-1/2" to 30"
8' 8"
25-1/2" to 30"
25-1/2" to 30"
8' 9"
25-1/2" to 30"
8' 10"
8' 11"
25-1/2" to 30"
9' 0"
25-1/2" to 30"
9' 1"
25-1/2" to 30"
25-1/2" to 30"
9' 2"
25-1/2" to 30"
9' 3"
9' 4"
25-1/2" to 30"
9' 5"
25-1/2" to 30"
25-1/2" to 30"
9' 6"
25-1/2" to 30"
9' 7"
25-1/2" to 30"
9' 8"
9' 9"
25-1/2" to 30"
9' 10"
25-1/2" to 30"
25-1/2" to 30"
9' 11"
25-1/2" to 30"
10' 0"
* Based on 36" countertop height.
ZV750SY Duct Cover Dimensions
Hood and
Accessory
A
ZXR758C
18-7/8"
ZXR7510C
18-7/8"
Installation Preparation
Recirculating
Accessory
9-1/4"
B
B
22-13/16"
34-5/8"
A
11-7/8"

POWER SUPPLY

IMPORTANT
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Code or
prevailing local codes and ordinances.

Electrical supply

This vent hood must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp
circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
• Route house wiring as close to the installation
location as possible. Wiring should enter at least 4"
above the bracket on the right side.
• Connect the wiring to the house wiring in
accordance with local codes.

Grounding instructions

The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING:
of the equipment-grounding conductor can result
in a risk of electric shock. Check with a qualified
electrician or service representative if you are in
doubt whether the appliance is properly grounded.
TOOLS AND MATERIALS
REQUIRED
(NOT SUPPLIED)
• Tape measure
• Knife
• Spirit level
• Wire cutter/stripper
• Wire nuts
• Electric drill and
appropriate bits
• Phillips and flat blade
screwdrivers
• Hammer
• Pliers
• Center punch
4
– (Please read carefully)
The improper connection
• 10 mm Hex wrench/socket
• Safety glasses
• Duct tape
• Gloves to protect against sharp
edges
• 120V 60Hz. 15 or 20 Amp, 2 wire
with ground. Properly grounded
branch circuit.
• Strain relief for junction cover.
• 6" round duct, length to suit
installation.

Advertisement