Status Code 13 - - Limit Circuit Lockout - Carrier PG9UAA Troubleshooting Manual

Variable speed, two-stage electronic condensing gas furnace
Table of Contents

Advertisement

STEP
10.
Disconnect the R thermostat lead.
11.
Do you have less than 19- -vac across R and C
trol?
12.
Replace transformer.
13.
The thermostat and/or thermostat wires are loading down the transformer. Replace the
thermostat or repair thermostat wires.
14.
Does the hot surface ignitor HSI come on during the cycle?
15.
Disconnect the humidifier lead from HUM terminal on variable speed furnace control.
16.
Does the furnace still alternately cycle induced draft motor IDM and blower motor BLWM
as described in Step 4.
17.
There is a direct short in wiring to humidifier solenoid coil, diode bridge(if used), or hu-
midifier solenoid coil.
18.
There is a short in the gas valve GV or wiring to gas valve GV. Refer to Appendix E to
check gas valve GV.
19.
There is a direct short in the ORANGE wire from the low heat pressure switch LPS.
20.
While the unit is operating in low heat jumper R and W2 thermostat terminals.
21.
Does the furnace abruptly shut down with no inducer post purge and then run blower mo-
tor BLWM for 90 seconds while AMBER LED status light flashes status code 12.
22.
Disconnect BROWN wire to gas valve GV.
23.
Does the furnace still abruptly shut down as described in Step 21.
24.
Replace gas valve.
25.
There is a direct short to ground in the GRAY or BROWN wires connected to the high heat
pressure switch HPS.
26.
Power to the furnace was probably interrupted or line voltage was too low during a call for
heat. This is normal operation. Go to the page number indicated in Index for the
CLEANUP AND STARTUP INSTRUCTIONS.
Status Code 13
LIMIT CIRCUIT LOCKOUT – Lockout occurs if the limit or flame rollout switch is open longer than 3 minutes or 10 suc-
cessive limit trips occurred during high- -heat. The variable speed furnace control will auto- -reset in 3 hours. Flame
roll- -out switch FRS requires manual- -reset.
STEP
1.
Remove the blower access panel. Disconnect the R thermostat lead from the furnace con-
trol board.
2.
Depress the door switch. Use piece of tape to hold it closed.
3.
Does status code 33 flash?
4.
Does a different status code flash?
5.
Go to page number indicated in the Index for the section covering the status code.
6.
Jumper R and W/W1 thermostat terminals.
7.
Observe the furnace operation for 25 minutes or until status code starts flashing.
8.
Does status code 33 flash?
9.
Does a different status code flash?
10.
Go to page number indicated in Index for CLEANUP AND START- -UP INSTRUC-
TIONS.
11.
Is 24- -vac across connector terminal PL1- -6 and C
trol?
12.
Replace the variable speed furnace control.
13.
Is 24- -vac across connector terminal PL1- -8 and C
trol?
14.
Turn power off.
15.
Do you have continuity across limit switch LS?
16.
Replace limit switch LS.
17.
Do you have continuity across the flame rollout switch FRS?
18.
Can flame rollout switch FRS be reset?
ACTION
V on the variable speed furnace con-
OM- - 24
ACTION
V on variable speed furnace con-
OM- - 24
V on variable speed furnace con-
OM- - 24
13
YES
NO
GO TO
11
12
13
9
9
15
19
16
18
17
8
8
8
21
22
26
23
25
24
9
8
INDEX
YES
NO
GO TO
2
3
11
4
5
6
INDEX
7
8
26
9
5
10
INDEX
13
12
10
12
14
15
17
16
10
25
18
20
19