Dimensions and Installation Information (in inches)
Electrical Requirements
Ranges must be supplied with 208/240V, 60Hz, and connected
to an individual, properly grounded branch circuit protected
by a circuit breaker or time-delay fuse. Install a 30-amp circuit
for 36" ranges. The receptacle must be a NEMA 14-50R device
to accept the four-prong plug on the range.
Universal Utility Locations
Locate gas and
electric as shown
Gas Supply
• The natural gas models are designed to
operate at 5" water column pressure.
For proper operation, the pressure of
the natural gas supplied to the regulator
must be between 7" and 13" water
column.
• The LP models are designed to operate
at 10" water column pressure. For
proper operation, the pressure of the LP
gas supplied to the regulator must be
between 11" and 13" water column.
For answers to your Monogram,
GE
appliance questions, visit our website at
®
ge.com or call GE Answer Center
800.626.2000.
36" Dual-Fuel Professional Range with 4 Burners and Griddle
GE Profile
or
®
service,
®
Optional Backsplash Accessories
The range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following
backsplash accessories are available, or a custom, non-
combustible backsplash can be used.
Order one with a 36"-wide range backsplash
ZX12B36PSS–12" backsplash
ZXADJB36PSS– 30"-36" adjustable-height backsplash with
warming shelf
Side View with a Backsplash
Specification Created 7/08
Listed by
Underwriters
Laboratories
130554

Advertisement

loading
Need help?

Need help?

Do you have a question about the Monogram ZDP364LDPSS and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Monogram zdp364ndpss