Advanced Controller setup procedure
Advanced Controller
•
Use with waters
having turbidity up
to 5.0NTU,
•
Has two output
terminals and
controls the
automated drain
and inlet valve.
Table 4-Advanced Controller Setup Procedure
Choosing a Controller Program
Controller-
Recommended
Program
household
occupancy
(persons)
Program 1
Up to 4
Program 2
Up to 4
Program 3
Up to 6
Table 5-MWF4100AWS and MWF4200AWS Controller Program Selection
MAYTAG Whole Home Water Filtration System Owners Manual MA1-5
November 2003
Advanced Controller
(Model MWF4300AWS)
1.
Modes: Use 'next' button to toggle through modes.
2.
Manual flush: Press 'next' until 'manual' is flashing. Press 'manual flush'
and hold. If held for longer than 10 seconds, drain valve remains open. Toggle
drain valve closed by pressing 'manual flush' once.
3.
Setting time of day: Press 'next' until 'set time' appears. Press 'enter'. Use
up/down arrows to set time of day. Press 'enter' to set.
4.
Set time of flush: Press 'next' until 'start time' appears. Press 'enter'. Use
up/down arrows to set time of flush. Press 'enter' to set.
5.
Setting program choice: Press 'next' until 'program' appears. Press 'enter'.
Use up/down arrows to select program choice. Press 'enter' to set.
(See Table 6 for programming choices.)
Source water
turbidity
(NTU)
<0.5
<0.5Peaks to
1.0NTU, <5%
of time
<0.5 Peaks to
1.0NTU, <5%
of time
Base Controller
Daily household
No.
water consumption
Flushes
per cycle
300Usgal/d
2
(1135L/d)
300Usgal/d
3
(1135L/d)
400Usgal/d
4
(1510L/d)
No.
Flush water used
System
per day
drains
(flow at
per cycle
7USGAL/min)
--
14USgal/d (53L/d)
--
21USgal/d (80L/d)
--
28USgal/d
(106L/d)
23