36" professional gas cooktop with 4 burners and grill

Advertisement

ZGU36N4RHSS
(Natural Gas)
ZGU36L4RHSS
(Liquid Propane)
Backsplash Accessories
The cooktop requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following
backsplash accessories are available, or a custom,
non-combustible backsplash can be used.
ZX12B36HSS, 12" backsplash
ZX22B36HSS, 22" backsplash with warming shelf
Backsplash with Warming Shelf
All Monogram
Professional Hoods feature infrared warming lights.
®
The 22"-high backsplash accessory with warming shelf is a perfect
complement when installed with the tapered or straight-sided hoods.
• Restaurant-Style Professional Hoods are shipped with a stainless
steel backsplash and warming shelf.
Side View with a Backsplash
26-5/8"
9-1/2"
3/4"
36" Min.
22" High
to Combustibles
22"
Backsplash
with Shelf
12"
12" High Backsplash
Specification Revised 10/05
130444
– GE Monogram 36" Professional Gas Cooktop with
4 Burners and Grill
12" Min. to Combustibles or
0" Min. to Combustibles
with 12" or 22" Backsplash
36" Min.
to
Combustibles
0" Clearance
Advance Planning for 36"
Professional Cooktops
Professional cooktops offer a number of choices in size and cooktop
configurations.
• All Professional cooktops are factory set for natural or liquid
propane gas. The correct model should be ordered for the
installation situation.
Note: Conversion kits (WB49X10132, Nat. to LP and WB49X10133,
LP to Nat.) are available if the wrong gas type was ordered. High
Altitude kit, WB49X10130, is also available. The kits must be installed
by a qualified service technician at additional cost.
2"
Locate gas
7"
inlet on
16"
back wall
or on floor
2" from
back wall
Electrical Requirements
Cooktops must be supplied with 120V, 60Hz, and connected to an
individual, properly grounded branch circuit protected by a 15 amp
circuit breaker or time-delay fuse.
605Dia84
Gas Supply
• Natural gas models are designed to operate at 5" water column
pressure. A regulator is required at the natural gas source to provide
maximum of 7" water pressure to the cooktop regulator.
• The liquid propane models are designed to operate at 10" water
column pressure. A regulator is required at the LP source to provide
maximum of 14" water pressure to the cooktop regulator.