Maintenance - MULTIQUIP Power WHISPERWATT DCA150SSI Operation And Parts Manual

Whisperwatt series 60hz generator (isuzu 6hkix diesel engine)
Hide thumbs Also See for Power WHISPERWATT DCA150SSI:
Table of Contents

Advertisement

Table 14.
check Engine Fluid Levels
check Air cleaner
check Battery Acid Level
check Fan Belt condition
check for Leaks
check for Loosening of Parts
Replace Engine Oil and Filter *
Engine
clean Air Filter
check Fuel Filter/Water Separator Bowl
clean Unit, Inside and Outside
change Fuel Filter
clean Radiator and check coolant Protection Level*
Replace Air Filter Element *
check all Hoses and clamps *
clean Inside of Fuel Tank
measure Insulation Resistance Over 3m ohms
Generator
check Rotor Rear Support Bearing
*
Replace engine oil and filter at 100 hours, first time only.
1
*
Add "Supplemental coolant Additives (ScA'S)" to recharge the engine coolant.
2
*
Replace primary air filter element when restriction indicator shows a vacuum of 625 mm (25 in. H20).
3
*
If blowby hose needs to be replaced, ensure that the slope of the blowby hose is at least a 1/2 inch per foot,
4
with no sags or dips that could collect moisture and/or oil.
general InSpeCtIon
Prior to each use, the generator should be cleaned and
inspected for deficiencies. check for loose, missing or
damaged nuts, bolts or other fasteners. Also check for
fuel, oil, and coolant leaks. Use Table 14 as a general
maintenance guideline. Engine Side, refer to the Engine
Instruction manual.
aIr Cleaner
Every 250 hours: Remove air cleaner element (Figure 56)
and clean the heavy duty paper element with light spray of
compressed air. Replace the air cleaner as needed.
Air cleaner with Dust Indicator
This indicator (Figure 56) is attached to the air cleaner.
When the air cleaner element is clogged, air intake
restriction becomes greater and the dust indicator signal
shows reD meaning the element needs changing or
service. After changing the air element, press the dust
indicator button to reset the indicator.
DCa150SSI/DCa150SSIu 60 hz gen. • operatIon anD partS manual — rev. #0 (11/23/09) — page 37
Inspection/maintenance
1
3
4
10 Hrs
250 Hrs 500 Hrs
DaIlY
X
X
X
X
X
X
X
X
X
X
2
X
figure 56.
Air Cleaner/Indicator
NOTICE
The air filter should not be changed until the indicator
reads "reD". Dispose of old air filter. It may not be
cleaned or reused.

MAINTENANCE

1000
Hrs
X
X
X
X
X
X

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power whisperwatt dca150ssiu

Table of Contents