Note For The Replacing Of Memory Ic - Aiwa HV-FX5100 Service Manual

Table of Contents

Advertisement

If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
ADDRESS
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
1.
Turn on the POWER and press both FF key and CH UP key on the set for more than 2 seconds.
2.
ADDRESS and DATA should appear as FIG 1.
3.
ADDRESS is now selected and should "blink". Using the SET + or - keys on the remote, step through the ADDRESS until
required ADDRESS to be changed is reached.
4.
Press ENTER to select DATA. When DATA is selected, it will "blink".
5.
Again, step through the DATA using SET + or - until required DATA value has been selected.
6.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
7.
Repeat steps 3 to 6 until all data has been checked.
8.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
The unit will now have the correct DATA for the new MEMORY IC.

NOTE FOR THE REPLACING OF MEMORY IC

DATA
ADDRESS
DATA
F1
D6
80
44
D7
00
24
D8
71
88
D9
9F
92
DA
02
45
DB
0A
00
DC
42
02
DD
35
09
DE
A3
03
DF
56
ADDRESS
DATA
ADDRESS
E0
76
EA
E1
5E
EB
E2
08
EC
E3
F0
ED
E4
01
EE
E5
F3
EF
E6
6C
F0
E7
2B
F1
E8
21
F2
E9
15
F3
Table 1
ADDRESS
DATA
Fig. 1
C4-1
DATA
ADDRESS
DATA
51
F4
41
5F
F5
83
09
F6
3D
F0
F7
6B
05
F8
0B
F3
F9
0C
00
FA
04
2F
FB
3A
DF
FC
99
41

Hide quick links: