ZVB30SH/BH/WH – GE Monogram 30" Telescopic Downdraft Vents
Venting Options
The downdraft vent is shipped with the
discharge outlet pointing straight down
and can be changed to a left- or right-side
discharge. For even more flexibility, the entire
blower and mounting plate can be adjusted
3-1/2" to the left or right sides.
Electrical and Gas Locations
Plan the placement of the electrical outlet
and gas (if used) carefully. Gas or electrical
outlets cannot be located on the back wall of
the cabinet because they may interfere with
the downdraft plenum.
• Install a standard electrical outlet within
reach of the vent's two-foot-long power
cord. Locate the outlet inside the cabinet
on the right side wall.
• If the vent is installed in combination with a
Monogram
gas cooktop, it may operate
®
from the same 120V standard duplex outlet.
• If the vent is installed in combination with a
Monogram electric cooktop, the vent must
operate from a separate 120V outlet.
Specification Created 10/03
130658
Discharge Down
(As Supplied)
682Dia49
Do Not Locate Gas or Electrical
Connections Within Shaded Area
29-1/2"
Electrical
Outlet
12" Above
Cabinet Floor
34" for 36" Models
28-1/2" for 30" Models
682Dia47
Discharge Left
682Dia50
R
For answers to your Monogram,
GE
®
GEAppliances.com or call GE Answer Center
service, 800.626.2000.
Discharge Right
682Dia51